Best Parts for Lenovo ThinkSystem ST650 V2
Complete compatibility guide for the ThinkSystem ST650 V2. 2 of the 1,926 parts listed are matched to the ThinkSystem ST650 V2 by part number; the other 1,924 are the component families ICD lists for it. Part-level fit is confirmed on every quote.
The Lenovo ThinkSystem ST650 V2 has 2 CPU sockets, up to 4TB DDR4 memory and 16 SFF drive bays. ICD Group lists 1,926 compatible parts for it in 14 component categories, led by SSD (738), Cable (190) and Riser (158), with 293 distinct configurations. 2 of the 1,926 parts listed are matched to the ThinkSystem ST650 V2 by part number; the other 1,924 are the component families ICD lists for it. Part-level fit is confirmed on every quote.
Server Specifications
| Brand | Lenovo |
| Model | ThinkSystem ST650 V2 |
| Generation | V2 |
| Type | Server |
| CPU Sockets | 2 |
| Maximum Memory | 4TB DDR4 |
| Drive Bays | 16 SFF |
| Lifecycle Status | End of sale |
| OEM End of Support | 2030-12-31 (ICD Care+ TPM continues coverage) |
| Processor Options | 1-2x 3rd Gen Intel Xeon Scalable (Ice Lake, to 36C/3.6GHz/250W) |
| Memory Configuration | 32x DDR4 RDIMM/3DS to 3200 MHz, max 4TB (5TB w/ 16x Optane PMem 200) |
| Drive Configurations | Up to 32x 2.5in hot-swap (16x NVMe) + 2x 5.25in bays, or 16x 3.5in (8x NVMe), or 12x 3.5in; + 2x M.2; max 983TB |
| Power Supply Options | Up to 2x hot-swap 750/1100/1800/2400W Platinum/Titanium (110V on 750/1100W) |
| RAID Controllers | Intel VROC SATA + NVMe; NVMe retimer; 12Gb RAID adapters (to 32-port, 8GB FBC); HBAs |
| Networking Options | 2x 10GBASE-T (BCM57416) + dedicated XCC |
| GPU Options | Up to 8x single-wide or 4x double-wide GPUs |
| Specification Source | Lenovo official documentation (verified 2026-07-02) |
Frequently Asked Questions
SSD for ThinkSystem ST650 V2
89 ssd configurations listed for the ThinkSystem ST650 V2, 738 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.
| Capacity | Interface | Form Factor | Speed | Parts | Example part numbers |
|---|---|---|---|---|---|
| 960 GB | SATA | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 38 | 01PE307, 4XB7A08503, 4XB7A10154 |
| 480 GB | SATA | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 35 | 4XB7A08502, 4XB7A10153, 4XB7A10196 |
| 1.92 TB | SATA | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 32 | 4XB7A08504, 4XB7A10155, 4XB7A10198 |
| 480 GB | SATA | 3.5" Large Form Factor (LFF) | Solid State (no rotational speed) | 31 | 4XB7A08492, 4XB7A08506, 4XB7A08515 |
| 3.84 TB | SATA | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 29 | 4XB7A08505, 4XB7A10156, 4XB7A10199 |
| 960 GB | SATA | 3.5" Large Form Factor (LFF) | Solid State (no rotational speed) | 27 | 4XB7A08507, 4XB7A10151, 4XB7A10159 |
| 240 GB | SATA | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 23 | 4XB7A10195, 4XB7A10237, 4XB7A10247 |
| 1.92 TB | NVMe | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 21 | 4XB7A13941, 4XB7A13976, 4XB7A17145 |
| 240 GB | SATA | 3.5" Large Form Factor (LFF) | Solid State (no rotational speed) | 21 | 4XB7A08491, 4XB7A10242, 4XB7A13625 |
| 3.84 TB | NVMe | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 21 | 4XB7A13942, 4XB7A13977, 4XB7A17124 |
| 1.92 TB | SATA | 3.5" Large Form Factor (LFF) | Solid State (no rotational speed) | 19 | 4XB7A08508, 4XB7A10160, 4XB7A10245 |
| 3.84 TB | SATA | 3.5" Large Form Factor (LFF) | Solid State (no rotational speed) | 18 | 4XB7A08509, 4XB7A10161, 4XB7A10246 |
| 7.68 TB | NVMe | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 17 | 4XB7A13943, 4XB7A17147, 4XB7A76733 |
| 1.6 TB | NVMe | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 16 | 4XB7A13967, 4XB7A17129, 4XB7A17152 |
| 800 GB | SAS | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 16 | 01DC452, 01DC457, 01DC477 |
| 15.36 TB | NVMe | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 15 | 4XB7A13631, 4XB7A81954, 4XB7A82369 |
| 3.2 TB | NVMe | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 15 | 4XB7A13970, 4XB7A17130, 4XB7A17153 |
| 7.68 TB | SATA | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 15 | 4XB7A10157, 4XB7A10200, 4XB7A13624 |
| 1.6 TB | SAS | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 13 | 01DC472, 4XB7A10231, 4XB7A13654 |
| 6.4 TB | NVMe | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 13 | 4XB7A13971, 4XB7A17133, 4XB7A17154 |
| 12.8 TB | NVMe | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 10 | 4XB7A17136, 4XB7A84056, 4XB7A93101 |
| 3.2 TB | SAS | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 9 | 00MM832, 4XB7A10232, 4XB7A17064 |
| 960 GB | NVMe | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 9 | 4XB7A13975, 4XB7A38170, 4XB7A79646 |
| 30.72 TB | NVMe | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 8 | 4XB7A81999, 4XB7A91176, 4XB7A93075 |
| Other ssd parts (no structured spec yet) | 89 | Browse all → | |||
+65 more ssd configurations (178 parts) →
Hard Drive for ThinkSystem ST650 V2
61 hard drive configurations listed for the ThinkSystem ST650 V2, 156 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.
| Capacity | Interface | Form Factor | Speed | Parts | Example part numbers |
|---|---|---|---|---|---|
| 2.4 TB | SAS | 2.5" Small Form Factor (SFF) | 10,000 RPM (10K) | 9 | 01GV182, 01KP508, 4XB7A83970 |
| 1.2 TB | SAS | 2.5" Small Form Factor (SFF) | 10,000 RPM (10K) | 7 | 00YK016, 01DC407, 01DC412 |
| 2 TB | SATA | 3.5" Large Form Factor (LFF) | 7,200 RPM (7.2K) | 6 | 4XB7A77446, 4XB7A77451, 4XB7A97044 |
| 1 TB | SATA | 3.5" Large Form Factor (LFF) | 7,200 RPM (7.2K) | 5 | 4XB7A77445, 4XB7A77450, 4XB7A97045 |
| 4 TB | SAS | 3.5" Large Form Factor (LFF) | 7,200 RPM (7.2K) | 5 | 4XB7A83972, 4XB7A88064, 4XB7B01235 |
| 4 TB | SATA | 3.5" Large Form Factor (LFF) | 7,200 RPM (7.2K) | 5 | 4XB7A77447, 4XB7B01236, 4XB7B01927 |
| 8 TB | SAS | 3.5" Large Form Factor (LFF) | 7,200 RPM (7.2K) | 5 | 4XB7A17222, 4XB7A83974, 4XB7B01239 |
| 8 TB | SATA | 3.5" Large Form Factor (LFF) | 7,200 RPM (7.2K) | 5 | 4XB7A17225, 4XB7A77449, 4XB7B01240 |
| 1.8 TB | SAS | 2.5" Small Form Factor (SFF) | 10,000 RPM (10K) | 4 | 01DC404, 4XB7A14113, 4XB7A14114 |
| 10 TB | SATA | 3.5" Large Form Factor (LFF) | 7,200 RPM (7.2K) | 4 | 4XB7A82681, 4XB7B01242, 7XB7A00054 |
| 12 TB | SAS | 3.5" Large Form Factor (LFF) | 7,200 RPM (7.2K) | 4 | 4XB7A17223, 4XB7A83976, 4XB7A93788 |
| 16 TB | SAS | 3.5" Large Form Factor (LFF) | 7,200 RPM (7.2K) | 4 | 4XB7A13911, 4XB7A80284, 4XB7A83978 |
| 2 TB | SAS | 2.5" Small Form Factor (SFF) | 7,200 RPM (7.2K) | 4 | 00NA497, 00NA500, 7XB7A00035 |
| 6 TB | SATA | 3.5" Large Form Factor (LFF) | 7,200 RPM (7.2K) | 4 | 4XB7A77448, 4XB7B01238, 7XB7A00052 |
| 600 GB | SAS | 2.5" Small Form Factor (SFF) | 10,000 RPM (10K) | 4 | 01DC427, 4XB7A83966, 7XB7A00025 |
| 10 TB | SAS | 3.5" Large Form Factor (LFF) | 7,200 RPM (7.2K) | 3 | 4XB7A82680, 4XB7B01241, 7XB7A00046 |
| 12 TB | SATA | 3.5" Large Form Factor (LFF) | 7,200 RPM (7.2K) | 3 | 4XB7A17226, 4XB7A93787, 7XB7A00068 |
| 16 TB | SATA | 3.5" Large Form Factor (LFF) | 7,200 RPM (7.2K) | 3 | 4XB7A13914, 4XB7A80285, 4XB7A93785 |
| 2 TB | SAS | 3.5" Large Form Factor (LFF) | 7,200 RPM (7.2K) | 3 | 4XB7B01233, 7XB7A00042, 7XB7A00065 |
| 20 TB | SAS | 3.5" Large Form Factor (LFF) | 7,200 RPM (7.2K) | 3 | 4XB7A80353, 4XB7A83980, 4XB7A93784 |
| 4 TB | NL-SAS | 3.5" Large Form Factor (LFF) | 7,200 RPM (7.2K) | 3 | 00YG675, 01DC489, 4XB7A14099 |
| 6 TB | SAS | 3.5" Large Form Factor (LFF) | 7,200 RPM (7.2K) | 3 | 4XB7B01237, 7XB7A00044, 7XB7A00048 |
| 12 TB | NL-SAS | 3.5" Large Form Factor (LFF) | 7,200 RPM (7.2K) | 2 | 01KP507, 4XB7A14104 |
| 14 TB | SAS | 3.5" Large Form Factor (LFF) | 7,200 RPM (7.2K) | 2 | 4XB7A13906, 4XB7A17224 |
| Other hard drive parts (no structured spec yet) | 9 | Browse all → | |||
+37 more hard drive configurations (47 parts) →
GPU for ThinkSystem ST650 V2
21 gpu configurations listed for the ThinkSystem ST650 V2, 138 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.
| Memory | Type | Interface | Parts | Example part numbers |
|---|---|---|---|---|
| 16 GB | — | — | 7 | 4C57A09498, 4X67A11524, 4X67A14926 |
| 24 GB | — | — | 6 | 4X67A13125, 4X67A71311, 4X67A76581 |
| 48 GB | — | — | 6 | 4X67A65441, 4X67A71310, 4X67A72593 |
| — | MI210 | — | 5 | 4X67A81102, 4X67A82325, 4X97A69627 |
| 32 GB | — | — | 4 | 4C57A09497, 4X67A12088, 4X67A13124 |
| 8 GB | — | — | 4 | 4X67A14934, 4X67A79777, 4X67A96431 |
| 80 GB | — | — | 3 | 4X67A76715, 4X67A82257, 4X67A86324 |
| 2 GB | — | — | 2 | 4X67A11584, 7C57A02894 |
| 20 GB | — | — | 2 | 4X67A76726, 4X67A97287 |
| 4 GB | — | — | 2 | 4X67A79778, 4X67B03688 |
| — | SFP Transceiver | — | 1 | 4TC7B10008 |
| 12 GB | — | — | 1 | 4X67A76720 |
| 141 GB | — | — | 1 | 4X67A97315 |
| 24 GB | P6000 | — | 1 | 7C57A02895 |
| 40 GB | — | — | 1 | 4X67A13135 |
| 400 GB | — | — | 1 | 4XC7B03668 |
| 5 GB | P2000 | — | 1 | 7C57A02877 |
| 5 GB | P2200 | — | 1 | 4X67A14935 |
| 64 GB | — | — | 1 | 4X67A76727 |
| 8 GB | P4000 | — | 1 | 4V17A10255 |
| 96 GB | — | — | 1 | 4X67B09287 |
| Other gpu parts (no structured spec yet) | 86 | Browse all → | ||
Networking for ThinkSystem ST650 V2
6 networking configurations listed for the ThinkSystem ST650 V2, 131 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.
| Speed | Connector | Ports | Parts | Example part numbers |
|---|---|---|---|---|
| — | SFP / SFP+ | — | 20 | 4XC7B00020, 7M17A04000, 7Z57A03541 |
| 10G | SFP28 Transceiver | — | 2 | 4TC7A88638, 7G17A03537 |
| — | SFP Transceiver | — | 1 | 4TC7A83365 |
| — | SFP+ Ethernet Transceiver | — | 1 | 7G17A03130 |
| 10G | SFP+ Transceiver | — | 1 | 4TC7A78615 |
| 25G | SFP28 Transceiver | — | 1 | 4M27A67041 |
| Other networking parts (no structured spec yet) | 105 | Browse all → | ||
RAID / HBA for ThinkSystem ST650 V2
17 raid / hba configurations listed for the ThinkSystem ST650 V2, 124 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.
| Controller | Interface | Speed | Parts | Example part numbers |
|---|---|---|---|---|
| RAID Controller | — | — | 53 | 4C57A16216, 4L47A92670, 4M17A12790 |
| RAID Controller | NVMe | — | 19 | 4L47A39164, 4X97A86435, 4XH7A60925 |
| Fibre Channel (FC) HBA | PCIe | 32 Gb/s | 11 | 4XC7A08250, 4XC7A08251, 4XC7A08276 |
| RAID Controller | SAS | — | 6 | 46C9115, 4M17A13565, 4M17A80602 |
| RAID Controller | SATA | — | 5 | 4XH7A60926, 4XH7A60977, 4XH7A80461 |
| SAS / SATA HBA | PCIe | — | 5 | 4Y37A09724, 4Y37A09725, 4Y37A78603 |
| SAS / SATA HBA | — | — | 4 | 4C57A16217, 4Y37A16228, 7Y37A01090 |
| Fibre Channel (FC) HBA | — | 16 Gb/s | 3 | 7ZT7A00520, 7ZT7A00521, 7ZT7A00522 |
| Fibre Channel (FC) HBA | PCIe | 64 Gb/s | 3 | 4XC7A77485, 4XC7A96458, 4XC7A96744 |
| Fibre Channel (FC) HBA | PCIe | 8 Gb/s | 2 | 4XC7A08220, 4XC7A08221 |
| PERC 9240 RAID Controller | SAS | 6 Gb/s | 2 | 03T6739, 91Y1859 |
| PERC 9350- RAID Controller | — | — | 2 | 4Y37A72485, 4Y37A72486 |
| PERC 9350-8I RAID Controller | — | — | 2 | 4Y37A72483, 4Y37A72484 |
| PERC 9450- RAID Controller | — | — | 2 | 4Y37A97937, 4Y37A97940 |
| — | PCIe | — | 1 | 7ZT7A00493 |
| PERC 9450-8I RAID Controller | — | — | 1 | 4Y37A97935 |
| RAID Controller | SAS / SATA | — | 1 | 4XH7A61096 |
| Other raid / hba parts (no structured spec yet) | 2 | Browse all → | ||
Processors for ThinkSystem ST650 V2
40 processors configurations listed for the ThinkSystem ST650 V2, 105 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.
| Clock | Cores / TDP | Parts | Example part numbers |
|---|---|---|---|
| 2.1 GHz | 24 Cores, 165W TDP | 7 | 4XG7A63397, 4XG7A63415, 4XG7A63417 |
| 2.2 GHz | 32 Cores, 205W TDP | 5 | 4XG7A63407, 4XG7A63437, 4XG7A63451 |
| 2.3 GHz | 20 Cores, 150W TDP | 5 | 4XG7A63410, 4XG7A63422, 4XG7A63454 |
| 2.0 GHz | 28 Cores, 205W TDP | 3 | 4XG7A63430, 4XG7A63473, 4XG7A63527 |
| 2.0 GHz | 32 Cores, 205W TDP | 3 | 4XG7A63436, 4XG7A63526, 4XG7A63579 |
| 2.1 GHz | 12 Cores, 120W TDP | 3 | 4XG7A63425, 4XG7A63468, 4XG7A63540 |
| 2.1 GHz | 36 Cores, 195W TDP | 3 | 4XG7A63404, 4XG7A63448, 4XG7A63531 |
| 2.2 GHz | 26 Cores, 185W TDP | 3 | 4XG7A63403, 4XG7A63535, 4XG7A63581 |
| 2.3 GHz | 32 Cores, 185W TDP | 3 | 4XG7A63654, 4XG7A63655, 4XG7A63657 |
| 2.4 GHz | 16 Cores, 135W TDP | 3 | 4XG7A63411, 4XG7A63455, 4XG7A63539 |
| 2.8 GHz | 24 Cores, 230W TDP | 3 | 4XG7A63537, 4XG7A63574, 4XG7A63578 |
| 2.8 GHz | 8 Cores, 105W TDP | 3 | 4XG7A63398, 4XG7A63443, 4XG7A63543 |
| 2.9 GHz | 16 Cores, 185W TDP | 3 | 4XG7A63401, 4XG7A63446, 4XG7A63536 |
| 3.0 GHz | 12 Cores, 150W TDP | 3 | 4XG7A63412, 4XG7A63456, 4XG7A63541 |
| 3.2 GHz | 8 Cores, 140W TDP | 3 | 4XG7A63434, 4XG7A63477, 4XG7A63565 |
| 2.1 GHz | 24 Cores, 150W TDP | 2 | 4XG7A63427, 4XG7A63470 |
| 2.2 GHz | 28 Cores, 165W TDP | 2 | 4XG7A63435, 4XG7A63478 |
| 2.2 GHz | 32 Cores, 185W TDP | 2 | 4XG7A63413, 4XG7A63457 |
| 2.3 GHz | 10 Cores, 105W TDP | 2 | 4XG7A63416, 4XG7A63459 |
| 2.3 GHz | 40 Cores, 270W TDP | 2 | 4XG7A63572, 4XG7A63576 |
| 2.4 GHz | 24 Cores, 185W TDP | 2 | 4XG7A63439, 4XG7A63480 |
| 2.4 GHz | 36 Cores, 250W TDP | 2 | 4XG7A63399, 4XG7A63444 |
| 2.4 GHz | 38 Cores, 270W TDP | 2 | 4XG7A63419, 4XG7A63462 |
| 2.5 GHz | 18 Cores, 150W TDP | 2 | 4XG7A63386, 4XG7A63392 |
| Other processors parts (no structured spec yet) | 7 | Browse all → | |
+16 more processors configurations (27 parts) →
Power for ThinkSystem ST650 V2
35 power configurations listed for the ThinkSystem ST650 V2, 57 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.
| Output | Type | Parts | Example part numbers |
|---|---|---|---|
| 2700W output | 80 PLUS Platinum, Hot-Swap | 5 | 4P57A82018, 4P57A82025, 4P57A88628 |
| 1100W output | 80 PLUS Platinum | 4 | 4P57A26293, 4P57A72671, 4P57A75974 |
| 1300W output | 80 PLUS Platinum, Hot-Swap | 4 | 4P57A88636, 4P57A89307, 4P57A89327 |
| 750W output | 80 PLUS Platinum | 4 | 4P57A26291, 4P57A72670, 4P57A75972 |
| 750W output | 80 PLUS Titanium | 3 | 4P57A26292, 4P57A82019, 7N67A00884 |
| 1300W output | 80 PLUS Platinum | 2 | 4P57A78363, 4P57A82024 |
| 1600W output | Hot-Swap | 2 | 4P57A78364, 4P57A82017 |
| 1800W output | 80 PLUS Platinum | 2 | 4P57A26294, 4P57A78362 |
| 240W output | — | 2 | 4X27A37265, 4X27A37266 |
| 500W output | 80 PLUS Platinum | 2 | 4P57A26290, 4P57A75971 |
| 584W output | — | 2 | 01DC149, 01DC150 |
| 750W output | 80 PLUS Titanium, Hot-Swap | 2 | 4P57A75973, 4P57A82020 |
| 1100W output | — | 1 | 4P57A15363 |
| 1100W output | 80 PLUS Platinum, Hot-Swap | 1 | 4P57A78361 |
| 1100W output | 80 PLUS Titanium | 1 | 4P57A72666 |
| 1100W output | High Efficiency, Hot-Swap | 1 | 4P57A89415 |
| 1100W output | Hot-Swap | 1 | 4P57A26296 |
| 1300W output | — | 1 | 4P57A88625 |
| 1300W output | 80 PLUS Titanium, Hot-Swap | 1 | 4P57A87628 |
| 1600W output | 80 PLUS Platinum | 1 | 7N67A00886 |
| 1600W output | 80 PLUS Titanium, Hot-Swap | 1 | 4P57A87750 |
| 1800W output | 80 PLUS Titanium | 1 | 4P57A78359 |
| 2000W output | 80 PLUS Platinum, Hot-Swap | 1 | 7N67A00887 |
| 2000W output | 80 PLUS Titanium | 1 | 4P57A88689 |
+11 more power configurations (11 parts) →
Memory for ThinkSystem ST650 V2
23 memory configurations listed for the ThinkSystem ST650 V2, 52 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.
| Capacity | Speed | Type | Parts | Example part numbers |
|---|---|---|---|---|
| 32 GB | 3200 MHz | RDIMM ECC Registered | 7 | 4X77A08634, 4X77A12188, 4X77A77064 |
| 16 GB | 2933 MHz | RDIMM ECC Registered | 5 | 4X77A12184, 4ZC7A08707, 4ZC7A08708 |
| 64 GB | 3200 MHz | RDIMM ECC Registered | 5 | 02JK971, 4X77A08635, 4X77A12189 |
| 128 GB | 3200 MHz | RDIMM ECC Registered | 4 | 4X77A08636, 4X77A75933, 4X77A91001 |
| 16 GB | 3200 MHz | RDIMM ECC Registered | 3 | 4X77A08632, 4X77A85855, 4ZC7A15121 |
| 64 GB | 2933 MHz | RDIMM ECC Registered | 3 | 4X77A12186, 4ZC7A08710, 4ZC7A08744 |
| 128 GB | 2933 MHz | RDIMM ECC Registered | 2 | 4X77A12187, 4ZC7A15113 |
| 16 GB | 2666 MHz | RDIMM ECC Registered | 2 | 7X77A01302, 7X77A01303 |
| 16 GB | 2666 MHz | UDIMM ECC Unbuffered | 2 | 4ZC7A08696, 4ZC7A08699 |
| 256 GB | 2933 MHz | RDIMM ECC Registered | 2 | 4X77A64957, 4ZC7A08727 |
| 32 GB | 2933 MHz | RDIMM ECC Registered | 2 | 4X77A12185, 4ZC7A08742 |
| 64 GB | 2666 MHz | LRDIMM ECC | 2 | 4X77A78614, 7X77A01305 |
| 8 GB | 2933 MHz | RDIMM ECC Registered | 2 | 4ZC7A08706, 4ZC7A08739 |
| 128 GB | 2666 MHz | RDIMM ECC Registered | 1 | 7X77A01307 |
| 256 GB | 2666 MHz | UDIMM ECC Unbuffered | 1 | 4ZC7A15110 |
| 256 GB | 3200 MHz | RDIMM ECC Registered | 1 | 4X77A75934 |
| 32 GB | 2666 MHz | RDIMM ECC Registered | 1 | 7X77A01304 |
| 32 GB | 2666 MHz | UDIMM ECC Unbuffered | 1 | 4ZC7A15142 |
| 512 GB | 2666 MHz | UDIMM ECC Unbuffered | 1 | 4ZC7A15111 |
| 512 GB | 3200 MHz | RDIMM ECC Registered | 1 | 4X77A75935 |
| 64 GB | 2666 MHz | RDIMM ECC Registered | 1 | 4ZC7A08716 |
| 64 GB | 3200 MHz | LRDIMM ECC | 1 | 4X77A08633 |
| 8 GB | 2666 MHz | RDIMM ECC Registered | 1 | 7X77A01301 |
| Other memory parts (no structured spec yet) | 1 | Browse all → | ||
Controllers for ThinkSystem ST650 V2
1 controllers configuration listed for the ThinkSystem ST650 V2, 2 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.
| Controller | Interface | Speed | Parts | Example part numbers |
|---|---|---|---|---|
| RAID Controller | — | — | 2 | 4Y37A16226, 4Y37A78599 |
Post-Warranty Support for ThinkSystem ST650 V2
ICD Care+ TPM covers the ThinkSystem ST650 V2 past OEM end-of-support: parts and on-site support at SLA levels set per contract, typically 40-60% less than OEM post-warranty support.
Learn About ICD Care+ →Frequently Asked Questions — ThinkSystem ST650 V2
What memory is compatible with the ThinkSystem ST650 V2?
The memory modules listed are the component families ICD lists for the ThinkSystem ST650 V2; part-level fit is confirmed on every quote. Maximum capacity: 4TB DDR4. Module type, speed and rank are confirmed against your configuration on the quote.
Does ICD ship ThinkSystem ST650 V2 parts to Egypt, UAE, KSA?
Yes. Egypt: same-day in Cairo Metro or 1-2 days. North Africa: 2-4 days. GCC (Saudi Arabia, UAE, Kuwait, Qatar, Bahrain, Oman) and Levant: 3-4 days. East Africa: 4-6 days. West Africa: 5-7 days. Southern Africa: 5-8 days. Europe: 3-5 days. North America: 5-7 days. Asia: 4-7 days. Express door-to-door from Cairo via DHL, Aramex or FedEx; customs clearance may add 1-3 days. Exact transit time is stated per quote. For NTRA-regulated networking parts bound for Egypt, the import route is stated per quote.
Is the ThinkSystem ST650 V2 still supported?
OEM support for the ThinkSystem ST650 V2 ends in December 2030. ICD Care+ TPM continues hardware support and parts at SLA levels set per contract.
How do I get a compatibility-verified quote?
Send your part list or workload requirement via the quote form or WhatsApp +20 104 022 22 14. We reply within 24 hours with a USD quotation matched by part number; the lead time is stated on each quote.
Are ICD parts for the ThinkSystem ST650 V2 new or refurbished?
Both, clearly labeled on every listing and quote: New, Renewed or Refurbished (tested). Every ICD part except consumables carries a warranty: 1 year included on drives, power supplies and other wear parts, 3 years included on CPUs, memory, networking and optics, and extendable up to 10 years.
Compatible Components
SSD
Cable
Riser
Hard Drive
GPU
Networking
RAID / HBA
Processors
Accessories
Power
Memory
Cooling
Caddy / Tray
Controllers
Related Resources
Need a custom configuration?
Our team can build a complete parts list for your ThinkSystem ST650 V2, with compatibility confirmed on the quote.
Get a Custom Quote