Best Parts for Lenovo ThinkSystem SR680A V3
Complete compatibility guide for the ThinkSystem SR680A V3. The parts listed are the component families ICD lists for the ThinkSystem SR680A V3; part-level fit is confirmed on every quote.
The Lenovo ThinkSystem SR680A V3 has 2 CPU sockets and 8 SFF drive bays. ICD Group lists 4,817 compatible parts for it in 10 component categories, led by Storage (1,613), Accessories (1,053) and Networking (667), with 501 distinct configurations. The parts listed are the component families ICD lists for the ThinkSystem SR680A V3; part-level fit is confirmed on every quote.
Server Specifications
| Brand | Lenovo |
| Model | ThinkSystem SR680A V3 |
| Generation | V3 |
| Type | Server |
| CPU Sockets | 2 |
| Drive Bays | 8 SFF |
| Lifecycle Status | Current |
| Processor Options | 2x 5th Gen Intel Xeon Scalable (Emerald Rapids, 64C, 350W); PCIe 5.0 |
| Memory Configuration | 32x DDR5 RDIMM (16/CPU) to 5600 MHz; max 4TB |
| Drive Configurations | Up to 16x 2.5in PCIe 5.0 NVMe hot-swap; + 2x M.2 boot (VROC option); max 245.76TB |
| Power Supply Options | 8x hot-swap 2600W Titanium, 220V, N+N |
| RAID Controllers | NVMe direct; M.2 Intel VROC boot RAID |
| Networking Options | 8x adapters to 400 Gb/s with GPUDirect; BlueField-3 200Gb; ConnectX-6 Lx mgmt |
| GPU Options | 8x NVIDIA H100/H200 SXM5 (700W, 80GB HBM3 / 141GB HBM3) or 8x Intel Gaudi 3 (128GB HBM2e); B200 variant LP2247 |
| Specification Source | Lenovo official documentation Lenovo Press LP1909 + LP2247 (lenovopress.lenovo.com) (verified 2026-07-02) |
Frequently Asked Questions
Storage for ThinkSystem SR680A V3
218 storage configurations listed for the ThinkSystem SR680A V3, 1,613 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.
| Capacity | Interface | Form Factor | Speed | Parts | Example part numbers |
|---|---|---|---|---|---|
| 960 GB | SATA | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 47 | 01PE307, 4XB7A08503, 4XB7A10154 |
| 480 GB | SATA | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 44 | 4XB7A08502, 4XB7A10153, 4XB7A10196 |
| 1.92 TB | SATA | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 42 | 4XB7A08504, 4XB7A10155, 4XB7A10198 |
| 3.84 TB | SATA | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 42 | 4XB7A08505, 4XB7A10156, 4XB7A10199 |
| 3.84 TB | NVMe | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 35 | 4XB7A13942, 4XB7A13977, 4XB7A17124 |
| 7.68 TB | NVMe | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 32 | 4XB7A13943, 4XB7A17147, 4XB7A76733 |
| 240 GB | SATA | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 31 | 4XB7A10195, 4XB7A10237, 4XB7A10247 |
| 1.92 TB | NVMe | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 28 | 4XB7A13941, 4XB7A13976, 4XB7A17145 |
| 15.36 TB | NVMe | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 26 | 4XB7A13631, 4XB7A81954, 4XB7A82369 |
| 3.84 TB | NVMe | — | Solid State (no rotational speed) | 26 | 4XB7A13998, 4XB7A38269, 4XB7A64141 |
| 7.68 TB | NVMe | — | Solid State (no rotational speed) | 26 | 4XB7A38270, 4XB7A64142, 4XB7A80499 |
| 1.6 TB | NVMe | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 24 | 4XB7A13967, 4XB7A17129, 4XB7A17152 |
| 7.68 TB | SATA | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 22 | 4XB7A10157, 4XB7A10200, 4XB7A13624 |
| 3.2 TB | NVMe | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 21 | 4XB7A13970, 4XB7A17130, 4XB7A17153 |
| 14 TB | SAS | 3.5" Large Form Factor (LFF) | 7,200 RPM (7.2K) | 20 | 4XB7A13906, 4XB7A17224, MG07SCA14TA |
| 8 TB | SATA | 3.5" Large Form Factor (LFF) | 7,200 RPM (7.2K) | 20 | 0B36418, 4XB7A17225, 4XB7A77449 |
| 1.92 TB | NVMe | — | Solid State (no rotational speed) | 19 | 4XB7A82855, 4XB7B09655, KCM6XRUL1T92 |
| 4 TB | SATA | 3.5" Large Form Factor (LFF) | 7,200 RPM (7.2K) | 19 | 4XB7A77447, 4XB7B01236, 4XB7B01927 |
| 6.4 TB | NVMe | 2.5" Small Form Factor (SFF) | Solid State (no rotational speed) | 19 | 4XB7A13971, 4XB7A17133, 4XB7A17154 |
| 10 TB | SATA | 3.5" Large Form Factor (LFF) | 7,200 RPM (7.2K) | 17 | 4XB7A82681, 4XB7B01242, 7XB7A00054 |
| 12 TB | SAS | 3.5" Large Form Factor (LFF) | 7,200 RPM (7.2K) | 17 | 4XB7A17223, 4XB7A83976, 4XB7A93788 |
| 18 TB | SAS | 3.5" Large Form Factor (LFF) | 7,200 RPM (7.2K) | 17 | 4XB7A38266, 4XB7A76340, MG09SCA18TA |
| 1.92 TB | NVMe | U.2 | Solid State (no rotational speed) | 16 | 4XB7A10175, 4XB7A14059, 4XB7A38196 |
| 16 TB | SAS | 3.5" Large Form Factor (LFF) | 7,200 RPM (7.2K) | 16 | 4XB7A13911, 4XB7A80284, 4XB7A83978 |
| Other storage parts (no structured spec yet) | 128 | Browse all → | |||
+194 more storage configurations (859 parts) →
Accessories for ThinkSystem SR680A V3
1 accessories configuration listed for the ThinkSystem SR680A V3, 1,053 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.
| Capacity | Type | Parts | Example part numbers |
|---|---|---|---|
| — | RAID Controller | 18 | 05-50038-00, 05-50038-02, 05-50039-00 |
| Other accessories parts (no structured spec yet) | 1,035 | Browse all → | |
Networking for ThinkSystem SR680A V3
21 networking configurations listed for the ThinkSystem SR680A V3, 667 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.
| Speed | Connector | Ports | Parts | Example part numbers |
|---|---|---|---|---|
| — | — | Dual Port (2) | 135 | AXX2P40FRTIOM, BCM5720-2P, BCM95720A2003G |
| — | SFP / SFP+ | — | 52 | 4XC7B00020, 7M17A04000, 7Z57A03541 |
| — | — | Quad Port (4) | 47 | BCM5719-4P, BCM957412-N410TGP0, BCM957412-P410TGP0 |
| 100G | QSFP28 Ethernet Transceiver | — | 13 | QSFP-100G-B20D4-I, QSFP-100G-B20U4-I, QSFP-100G-DR-S |
| 10G | SFP+ Ethernet Transceiver | — | 13 | 407-BBOP, SFP-10G-BX40D-I, SFP-10G-BX40U-I |
| 40G | QSFP+ Ethernet Transceiver | — | 11 | 00FP652, 00W0039, 95Y3461 |
| 100G | QSFP28 Transceiver | — | 7 | MMA1B00-E100D, QSFP-100G-4W40-I, QSFP-100G-CWDM4-S |
| 10G | SFP+ Transceiver | — | 5 | 42C1816, 46C9297, 46W4236 |
| — | SFP+ Transceiver | — | 4 | FTLF8529P3BCV-QL, FTLF8529P4BCV-QL, FTLF8532P4BCV-QL |
| 1G | SFP Ethernet Transceiver | — | 4 | 407-BBOS, GLC-LH-SMD, GLC-SX-MMD |
| — | QSFP28 Ethernet Transceiver | — | 3 | MMA1B00-C100D, MMA1L30-CM, MMS1C10-CM |
| — | SFP28 Ethernet Transceiver | — | 2 | MMA2P00-AS, MMA2P00-AS-SP |
| 10G | SFP28 Transceiver | — | 2 | 4TC7A88638, 7G17A03537 |
| 25G | SFP28 Ethernet Transceiver | — | 2 | SFP-25G-LR-S, SFP-25G-SR-S |
| 40G | QSFP+ Transceiver | — | 2 | 00D9552, FET-40G |
| — | QSFP+ Ethernet Transceiver | — | 1 | MMA1T00-VS |
| — | QSFP28 Transceiver | — | 1 | CVR-QSFP28-SFP25G |
| — | SFP Transceiver | — | 1 | 4TC7A83365 |
| — | SFP+ Ethernet Transceiver | — | 1 | 7G17A03130 |
| 200G | QSFP+ Transceiver | — | 1 | MMA1T00-HS |
| 25G | SFP28 Transceiver | — | 1 | 4M27A67041 |
| Other networking parts (no structured spec yet) | 359 | Browse all → | ||
Controllers for ThinkSystem SR680A V3
50 controllers configurations listed for the ThinkSystem SR680A V3, 447 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.
| Controller | Interface | Speed | Parts | Example part numbers |
|---|---|---|---|---|
| RAID Controller | — | — | 69 | 2275400-R, 2283400-R, 3204C8IX2S |
| SAS / SATA HBA | — | — | 44 | 05-25688-00, 05-50044-00, 05-50065-00 |
| Fibre Channel (FC) HBA | — | — | 43 | LPe31000-M6, LPe31002-M6, LPe31004-M6 |
| Fibre Channel (FC) HBA | PCIe | 16 Gb/s | 36 | LPe16000-M6, LPe16000B-AP, LPe16000B-M6 |
| Fibre Channel (FC) HBA | PCIe | 32 Gb/s | 33 | 4XC7A08250, 4XC7A08251, 4XC7A08276 |
| SAS / SATA HBA | PCIe | — | 30 | 03-25600-01B, 05-25600-00, 05-50118-00 |
| RAID Controller | NVMe | — | 22 | 3204C8IXS, 3254C16IX2S, 3254C16IXS |
| RAID Controller | SAS | — | 18 | 2279700-R, 2279800-R, 2279900-R |
| Fibre Channel (FC) HBA | — | 16 Gb/s | 16 | 7ZT7A00520, 7ZT7A00521, 7ZT7A00522 |
| Fibre Channel (FC) HBA | PCIe | 64 Gb/s | 16 | 4XC7A77485, 4XC7A96458, 4XC7A96744 |
| RAID Controller | SAS / SATA | 12 Gb/s | 15 | 2277500-R, 2277600-R, 2287101-R |
| RAID Controller | SAS / SATA | 6 Gb/s | 14 | 2270100-R, 2270800-R, 2271700-R |
| Fibre Channel (FC) HBA | — | 32 Gb/s | 11 | LPe32000-M2-D, LPe32000-M2-L, LPe32002-M2-D |
| Fibre Channel (FC) HBA | — | 64 Gb/s | 5 | LPe36000-D, LPe36000-M64-D, LPe36002-D |
| RAID Controller | SATA | — | 5 | 4XH7A60926, 4XH7A60977, 4XH7A80461 |
| PERC 9380- RAID Controller | SAS / SATA | 12 Gb/s | 4 | 05-25190-02, 05-25528-04, 05-25528-06 |
| — | PCIe | — | 3 | 7ZT7A00493, QLE4060C-CK, QLE4062C-CK |
| PERC 9361- RAID Controller | SAS / SATA | 12 Gb/s | 3 | 05-25699-00, 05-25708-00, LSI00462 |
| RAID Controller | SAS / SATA | — | 3 | 2244100-R, 2244300-R, 4XH7A61096 |
| Fibre Channel (FC) HBA | PCIe | 8 Gb/s | 2 | 4XC7A08220, 4XC7A08221 |
| PERC 9240 RAID Controller | SAS | 6 Gb/s | 2 | 03T6739, 91Y1859 |
| PERC 9350- RAID Controller | — | — | 2 | 4Y37A72485, 4Y37A72486 |
| PERC 9350-8I RAID Controller | — | — | 2 | 4Y37A72483, 4Y37A72484 |
| PERC 9361-8I RAID Controller | SAS / SATA | 12 Gb/s | 2 | 05-25420-08, 05-25420-10 |
| Other controllers parts (no structured spec yet) | 18 | Browse all → | ||
+26 more controllers configurations (29 parts) →
GPU for ThinkSystem SR680A V3
55 gpu configurations listed for the ThinkSystem SR680A V3, 407 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.
+31 more gpu configurations (52 parts) →
Processors for ThinkSystem SR680A V3
90 processors configurations listed for the ThinkSystem SR680A V3, 317 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.
+66 more processors configurations (132 parts) →
Memory for ThinkSystem SR680A V3
30 memory configurations listed for the ThinkSystem SR680A V3, 119 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.
| Capacity | Speed | Type | Parts | Example part numbers |
|---|---|---|---|---|
| 32 GB | 4800 MHz | RDIMM ECC Registered | 14 | 4X77A77030, 4X77A77031, 4X77A77483 |
| 64 GB | 4800 MHz | RDIMM ECC Registered | 13 | 4X77A77032, 4X77A77033, 4X77A81441 |
| 32 GB | 5600 MHz | RDIMM ECC Registered | 9 | 4X77A88049, 4X77A88050, 4X77A88051 |
| 64 GB | 5600 MHz | RDIMM ECC Registered | 9 | 4X77A88052, 4X77A90992, 4X77B00032 |
| 128 GB | 5600 MHz | RDIMM ECC Registered | 8 | 4X77A88054, 4X77A93887, 4X77A96982 |
| 96 GB | 5600 MHz | RDIMM ECC Registered | 7 | 4X77A88053, 4X77A88058, 4X77B00033 |
| 16 GB | 4800 MHz | RDIMM ECC Registered | 6 | 4X77A77029, 4X77A81437, HMCG78AEBRA107N |
| 48 GB | 5600 MHz | RDIMM ECC Registered | 6 | 4X77A88057, 4X77A88639, HMCGY4AGBRB |
| 128 GB | 4800 MHz | RDIMM ECC Registered | 4 | 4X77A77034, 4X77A81443, HMCT04MEERA |
| 96 GB | 4800 MHz | RDIMM ECC Registered | 4 | 4X77A81448, 4X77A87034, HMCGM4MEBRB |
| 16 GB | 5600 MHz | RDIMM ECC Registered | 3 | 4X77A99751, HMCG78AGBRA107N, HMCG78AGBRA109N |
| 256 GB | 4800 MHz | RDIMM ECC Registered | 3 | 4X77A77035, 4X77A81444, HMCT08MEERA |
| 48 GB | 4800 MHz | RDIMM ECC Registered | 3 | 4X77A81447, HMCGY4MEBRB, HMCGY8MEBRB |
| 96 GB | 6400 MHz | RDIMM ECC Registered | 3 | HMCGM4AHBRB, HMCGM4MHBRB, HMCGM4MHBRB109N |
| 16 GB | 5200 MHz | RDIMM ECC Registered | 2 | HMCG78MFBRA109N, HMCG78MFBRA115N |
| 16 GB | 6400 MHz | RDIMM ECC Registered | 2 | HMCG78AHBRA, HMCG78AHBRA109N |
| 24 GB | 5600 MHz | RDIMM ECC Registered | 2 | 4X77A88056, HMCG84MGBRA |
| 256 GB | 5600 MHz | RDIMM ECC Registered | 2 | 4X77A88055, HMCT08AGERA |
| 32 GB | 6400 MHz | RDIMM ECC Registered | 2 | HMCG84AHBRA, HMCG88AHBRA |
| 48 GB | 6400 MHz | RDIMM ECC Registered | 2 | HMCGY4MHBRB, HMCGY8MHBRB |
| 64 GB | 6400 MHz | RDIMM ECC Registered | 2 | HMCG94AHBRA109N, HMCG94AHBRA481N |
| — | — | RDIMM | 1 | 4X77A88087 |
| 128 GB | 5200 MHz | RDIMM ECC Registered | 1 | HMCT04MFBRA |
| 128 GB | 6400 MHz | RDIMM ECC Registered | 1 | HMCT04AHERA |
| Other memory parts (no structured spec yet) | 4 | Browse all → | ||
+6 more memory configurations (6 parts) →
Power Supplies for ThinkSystem SR680A V3
36 power supplies configurations listed for the ThinkSystem SR680A V3, 60 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.
| Output | Type | Parts | Example part numbers |
|---|---|---|---|
| 2700W output | 80 PLUS Platinum, Hot-Swap | 5 | 4P57A82018, 4P57A82025, 4P57A88628 |
| 1100W output | 80 PLUS Platinum | 4 | 4P57A26293, 4P57A72671, 4P57A75974 |
| 1300W output | 80 PLUS Platinum, Hot-Swap | 4 | 4P57A88636, 4P57A89307, 4P57A89327 |
| 750W output | 80 PLUS Platinum | 4 | 4P57A26291, 4P57A72670, 4P57A75972 |
| 750W output | 80 PLUS Titanium | 3 | 4P57A26292, 4P57A82019, 7N67A00884 |
| 1300W output | 80 PLUS Platinum | 2 | 4P57A78363, 4P57A82024 |
| 1600W output | Hot-Swap | 2 | 4P57A78364, 4P57A82017 |
| 1800W output | 80 PLUS Platinum | 2 | 4P57A26294, 4P57A78362 |
| 180W output | — | 2 | L08261-006, L70042-006 |
| 240W output | — | 2 | 4X27A37265, 4X27A37266 |
| 500W output | 80 PLUS Platinum | 2 | 4P57A26290, 4P57A75971 |
| 584W output | — | 2 | 01DC149, 01DC150 |
| 750W output | 80 PLUS Titanium, Hot-Swap | 2 | 4P57A75973, 4P57A82020 |
| 1100W output | — | 1 | 4P57A15363 |
| 1100W output | 80 PLUS Platinum, Hot-Swap | 1 | 4P57A78361 |
| 1100W output | 80 PLUS Titanium | 1 | 4P57A72666 |
| 1100W output | High Efficiency, Hot-Swap | 1 | 4P57A89415 |
| 1100W output | Hot-Swap | 1 | 4P57A26296 |
| 1300W output | — | 1 | 4P57A88625 |
| 1300W output | 80 PLUS Titanium, Hot-Swap | 1 | 4P57A87628 |
| 1600W output | 80 PLUS Platinum | 1 | 7N67A00886 |
| 1600W output | 80 PLUS Titanium, Hot-Swap | 1 | 4P57A87750 |
| 1800W output | 80 PLUS Titanium | 1 | 4P57A78359 |
| 2000W output | 80 PLUS Platinum, Hot-Swap | 1 | 7N67A00887 |
| Other power supplies parts (no structured spec yet) | 1 | Browse all → | |
+12 more power supplies configurations (12 parts) →
Post-Warranty Support for ThinkSystem SR680A V3
ICD Care+ TPM covers the ThinkSystem SR680A V3 past OEM end-of-support: parts and on-site support at SLA levels set per contract, typically 40-60% less than OEM post-warranty support.
Learn About ICD Care+ →Frequently Asked Questions — ThinkSystem SR680A V3
What memory is compatible with the ThinkSystem SR680A V3?
The memory modules listed are the component families ICD lists for the ThinkSystem SR680A V3; part-level fit is confirmed on every quote. Maximum capacity: per OEM spec sheet. Module type, speed and rank are confirmed against your configuration on the quote.
Does ICD ship ThinkSystem SR680A V3 parts to Egypt, UAE, KSA?
Yes. Egypt: same-day in Cairo Metro or 1-2 days. North Africa: 2-4 days. GCC (Saudi Arabia, UAE, Kuwait, Qatar, Bahrain, Oman) and Levant: 3-4 days. East Africa: 4-6 days. West Africa: 5-7 days. Southern Africa: 5-8 days. Europe: 3-5 days. North America: 5-7 days. Asia: 4-7 days. Express door-to-door from Cairo via DHL, Aramex or FedEx; customs clearance may add 1-3 days. Exact transit time is stated per quote. For NTRA-regulated networking parts bound for Egypt, the import route is stated per quote.
How do I get a compatibility-verified quote?
Send your part list or workload requirement via the quote form or WhatsApp +20 104 022 22 14. We reply within 24 hours with a USD quotation matched by part number; the lead time is stated on each quote.
Are ICD parts for the ThinkSystem SR680A V3 new or refurbished?
Both, clearly labeled on every listing and quote: New, Renewed or Refurbished (tested). Every ICD part except consumables carries a warranty: 1 year included on drives, power supplies and other wear parts, 3 years included on CPUs, memory, networking and optics, and extendable up to 10 years.
Compatible Components
Storage
Accessories
Networking
Controllers
GPU
Processors
Complete Server
Memory
Power Supplies
Cooling
Related Resources
Need a custom configuration?
Our team can build a complete parts list for your ThinkSystem SR680A V3, with compatibility confirmed on the quote.
Get a Custom Quote