Trusted Since 2005| +202 2705 2005| [email protected]| 1 to 10 Year Warranty| Ships Worldwide to 100+ Countries| Every Part Tested & Warranted| 500,000+ Enterprise Parts| Dell · HPE · IBM · Lenovo · Cisco|Trusted Since 2005| +202 2705 2005| [email protected]| 1 to 10 Year Warranty| Ships Worldwide to 100+ Countries| Every Part Tested & Warranted| 500,000+ Enterprise Parts| Dell · HPE · IBM · Lenovo · Cisco

Best Parts for Dell PowerEdge R760xd

Complete compatibility guide for the PowerEdge R760xd (16G). The parts listed are the component families ICD lists for the PowerEdge R760xd; part-level fit is confirmed on every quote.

6Categories
3,013Compatible Parts
4TB DDR5Max Memory
24 SFFDrive Bays

The Dell PowerEdge R760xd (16G) has 2 CPU sockets, up to 4TB DDR5 memory and 24 SFF drive bays. ICD Group lists 3,013 compatible parts for it in 6 component categories, led by Storage (2,547), Controllers (273) and Power & Cooling (98), with 125 distinct configurations. The parts listed are the component families ICD lists for the PowerEdge R760xd; part-level fit is confirmed on every quote.

Server Specifications

BrandDell
ModelPowerEdge R760xd
Generation16G
TypeServer
CPU Sockets2
Maximum Memory4TB DDR5
Drive Bays24 SFF
Lifecycle StatusCurrent

Storage for PowerEdge R760xd

58 storage configurations listed for the PowerEdge R760xd, 2,547 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.

CapacityInterfaceForm FactorSpeedPartsExample part numbers
1.2 TBSAS2.5" Small Form Factor (SFF)10,000 RPM (10K)281001M0D, 00KV02, 019FP0
600 GBSAS2.5" Small Form Factor (SFF)10,000 RPM (10K)260010DR3, 029V4, 03J10Y
3.84 TBSAS2.5" Small Form Factor (SFF)Solid State (no rotational speed)231003XGD, 01JV0K, 021CT4
300 GBSAS2.5" Small Form Factor (SFF)15,000 RPM (15K)18800RVDT, 01D94D, 0377CF
1.92 TBSAS2.5" Small Form Factor (SFF)Solid State (no rotational speed)167002X38, 0086DD, 00FYFW
800 GBSAS2.5" Small Form Factor (SFF)Solid State (no rotational speed)16100FRVY, 02P42R, 03FWXV
1.8 TBSAS2.5" Small Form Factor (SFF)10,000 RPM (10K)15700J77H, 00VPTJ, 01GXN0
900 GBSAS2.5" Small Form Factor (SFF)10,000 RPM (10K)14601M1K4, 01X09G, 02RR9T
600 GBSAS2.5" Small Form Factor (SFF)15,000 RPM (15K)13801W7HC, 01W95C, 0252H
1.6 TBSAS2.5" Small Form Factor (SFF)Solid State (no rotational speed)115014PN0, 04P9YK, 05HR3X
960 GBSAS2.5" Small Form Factor (SFF)Solid State (no rotational speed)108004RKT, 009JJC, 032T3C
300 GBSAS2.5" Small Form Factor (SFF)10,000 RPM (10K)800148J7, 029MMM, 02M5JK
400 GBSAS2.5" Small Form Factor (SFF)Solid State (no rotational speed)78003VVP, 00GRY6, 022RKC
900 GBSAS2.5" Small Form Factor (SFF)15,000 RPM (15K)7401053F, 01M69V, 02J16V
480 GBSAS2.5" Small Form Factor (SFF)Solid State (no rotational speed)64005H78, 006VJ7, 03PR5C
2.4 TB—2.5" Small Form Factor (SFF)10,000 RPM (10K)43010N35, 036YG1, 03G5K5
7.68 TBSAS2.5" Small Form Factor (SFF)Solid State (no rotational speed)420050N5, 04RNJR, 050N5
2.4 TBSAS2.5" Small Form Factor (SFF)10,000 RPM (10K)3109F0N8, 0GND9R, 0W9MNK
200 GBSAS2.5" Small Form Factor (SFF)Solid State (no rotational speed)27001Y7M, 01Y7M, 08YPYK
1.8 TB—2.5" Small Form Factor (SFF)10,000 RPM (10K)2600WRRF, 0F66TR, 0F91TM
146 GBSAS2.5" Small Form Factor (SFF)10,000 RPM (10K)150CM318, 341-4732, 342-2015
146 GBSAS2.5" Small Form Factor (SFF)15,000 RPM (15K)12341-8972, 341-9875, 342-2035
500 GBSAS2.5" Small Form Factor (SFF)7,200 RPM (7.2K)110D7MYF, 0K831N, 0NV0G9
73 GBSAS2.5" Small Form Factor (SFF)15,000 RPM (15K)11341-4820, G108N, HR044
Other storage parts (no structured spec yet)1Browse all →

+34 more storage configurations (80 parts) →

Controllers for PowerEdge R760xd

21 controllers configurations listed for the PowerEdge R760xd, 273 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.

ControllerInterfaceSpeedPartsExample part numbers
Fibre Channel (FC) HBAPCIe16 Gb/s127013MJR, 01KK8W, 01KPGF
—PCIe—3101NNXD, 02PHG9, 03KC27
SAS / SATA HBA——2001HD39, 0T93GD, 0VYM4
Fibre Channel (FC) HBAPCIe—19050JV, 0GVF0M, 0RXNT1
Fibre Channel (FC) HBA—32 Gb/s16403-BBLV, 403-BBLX, 403-BBMC
Fibre Channel (FC) HBA—16 Gb/s9403-BBLQ, 403-BBMB, 403-BBMH
SAS / SATA HBAPCIe—9083DH4, 1KH9T, 2XVTC
PERC H965I RAID Controller——803KWJN, 0GT7YG, 0WXXHY
RAID ControllerSAS—66TFJ5, 8NX75, 9MHYN
Fibre Channel (FC) HBA—64 Gb/s5540-BDNO, 540-BDNS, 540-BDRP
Fibre Channel (FC) HBA—8 Gb/s3406-BBDS, 406-BBGR, 635X7
PERC H965I RAID ControllerNVMe—3405-ABDM, 405-ABDN, W2C1K
RAID Controller——34G20M, 5Y1HD, J6RYT
Fibre Channel (FC) HBAPCIe8 Gb/s2RW9KF, VX60F
PERC H355 RAID ControllerSAS—20TKK9K, 0VCV6T
PERC H355I RAID Controller——2TKK9K, VCV6T
PERC H965E RAID Controller——2405-BBBT, VWHMH
Fibre Channel (FC) HBA——173TM8
Fibre Channel (FC) HBAPCIe32 Gb/s1VPDGC
PERC H710 RAID Controller——17VJMH
PERC H975I RAID ControllerNVMe—12PG59
Other controllers parts (no structured spec yet)2Browse all →

Power & Cooling for PowerEdge R760xd

7 power & cooling configurations listed for the PowerEdge R760xd, 98 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.

OutputTypePartsExample part numbers
1100W output80 PLUS Platinum4201JDDV, 038GYJ, 06D1MJ
1100W outputHot-Swap3801Y45R, 03MJJP, 03MMJ3
1100W output—110WPJC6, 3MJPP, 450
1100W output80 PLUS Titanium30FR0KX, FR0KX, J9N6W
1100W output80 PLUS Titanium, Hot-Swap2450-ALEM, T2GYV
1100W output80 PLUS Platinum, Hot-Swap19TMRF
1100W outputHot-Swap, Redundant1450-AEEQ

Processors for PowerEdge R760xd

33 processors configurations listed for the PowerEdge R760xd, 39 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.

ClockCores / TDPPartsExample part numbers
2.0 GHz16 Cores, 150W TDP2338-CHSL, 338-CLVY
2.0 GHz52 Cores, 350W TDP2338-CHCV, 338-CHPN
2.1 GHz32 Cores, 225W TDP2338-CKTF, SRMGN
2.1 GHz48 Cores, 350W TDP2338-CHDD, 338-CHOV
2.5 GHz—2RK389, SLARP
2.8 GHz32 Cores, 300W TDP2338-CKTD, 338-CPBT
1.9 GHz24 Cores1SRMGY
1.9 GHz64 Cores1SRN55
2.0 GHz12 Cores1SRMGE
2.0 GHz16 Cores1SRMH2
2.0 GHz20 Cores1SRMGG
2.0 GHz24 Cores1SRMGH
2.0 GHz28 Cores1SRMGL
2.0 GHz32 Cores1SRMGM
2.0 GHz32 Cores, 205W TDP1338-CLVZ
2.0 GHz36 Cores1SRM7W
2.0 GHz36 Cores, 300W TDP1338-CBXW
2.1 GHz32 Cores1SRM7A
2.1 GHz32 Cores, 270W TDP1338-CKYZ
2.2 GHz32 Cores1SRMH3
2.4 GHz12 Cores1SRN60
2.4 GHz32 Cores1SRMGW
2.4 GHz32 Cores, 250W TDP1338-CLVV
2.5 GHz16 Cores1SRMGF

+9 more processors configurations (9 parts) →

Networking for PowerEdge R760xd

1 networking configuration listed for the PowerEdge R760xd, 34 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.

SpeedConnectorPortsPartsExample part numbers
25G EthernetSFP28Dual Port (2)3400M95, 06WMMV, 20NJD

Memory for PowerEdge R760xd

5 memory configurations listed for the PowerEdge R760xd, 22 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.

CapacitySpeedTypePartsExample part numbers
64 GB4800 MHzRDIMM ECC Registered6370-AGZQ, 370-AGZR, 370-AHIB
32 GB4800 MHzRDIMM ECC Registered5370-AGYZ, 370-AGZP, AC239378
128 GB4800 MHzRDIMM ECC Registered4370-AGRG, AC448843, AC449974
16 GB4800 MHzRDIMM ECC Registered4370-AGZN, 370-AGZO, AC239377
256 GB4800 MHzRDIMM ECC Registered3370-AHHF, 370-AHIE, 370-BBHY

Post-Warranty Support for PowerEdge R760xd

ICD Care+ TPM covers the PowerEdge R760xd past OEM end-of-support: parts and on-site support at SLA levels set per contract, typically 40-60% less than OEM post-warranty support.

Learn About ICD Care+ →

Frequently Asked Questions — PowerEdge R760xd

What memory is compatible with the PowerEdge R760xd?

The memory modules listed are the component families ICD lists for the PowerEdge R760xd; part-level fit is confirmed on every quote. Maximum capacity: 4TB DDR5. Module type, speed and rank are confirmed against your configuration on the quote.

Does ICD ship PowerEdge R760xd parts to Egypt, UAE, KSA?

Yes. Egypt: same-day in Cairo Metro or 1-2 days. North Africa: 2-4 days. GCC (Saudi Arabia, UAE, Kuwait, Qatar, Bahrain, Oman) and Levant: 3-4 days. East Africa: 4-6 days. West Africa: 5-7 days. Southern Africa: 5-8 days. Europe: 3-5 days. North America: 5-7 days. Asia: 4-7 days. Express door-to-door from Cairo via DHL, Aramex or FedEx; customs clearance may add 1-3 days. Exact transit time is stated per quote. For NTRA-regulated networking parts bound for Egypt, the import route is stated per quote.

How do I get a compatibility-verified quote?

Send your part list or workload requirement via the quote form or WhatsApp +20 104 022 22 14. We reply within 24 hours with a USD quotation matched by part number; the lead time is stated on each quote.

Are ICD parts for the PowerEdge R760xd new or refurbished?

Both, clearly labeled on every listing and quote: New, Renewed or Refurbished (tested). Every ICD part except consumables carries a warranty: 1 year included on drives, power supplies and other wear parts, 3 years included on CPUs, memory, networking and optics, and extendable up to 10 years.

Compatible Components

Need a custom configuration?

Our team can build a complete parts list for your PowerEdge R760xd, with compatibility confirmed on the quote.

Get a Custom Quote
Worldwide Shipping

Fast delivery to 100+ countries

Tested & Warranted

Every part fully tested before shipping

Enterprise Grade

Dell, HPE, Lenovo & Cisco parts

Dedicated Support

Expert team for quotes & technical help