Best Parts for Lenovo ThinkSystem SR670 V2
ICD, an enterprise server parts and services company based in Cairo, Egypt, since 2005, lists 4,427 catalogue parts in 10 categories for the Lenovo ThinkSystem SR670 V2 and ships worldwide from Cairo by express courier.
Parts guide for the ThinkSystem SR670 V2. The parts listed are the component families ICD lists for the ThinkSystem SR670 V2; part-level fit is confirmed on every quote.
The Lenovo ThinkSystem SR670 V2 has 2 CPU sockets, up to 2TB DDR4 memory and 8 SFF drive bays. ICD Group lists 4,427 parts for it in 10 component categories, led by Storage (1,536), Accessories (1,070) and Networking (651), with 426 distinct configurations. The parts listed are the component families ICD lists for the ThinkSystem SR670 V2; part-level fit is confirmed on every quote.
Server Specifications
| Brand | Lenovo |
| Model | ThinkSystem SR670 V2 |
| Generation | V2 |
| Type | Server |
| CPU Sockets | 2 |
| Maximum Memory | 2TB DDR4 |
| Drive Bays | 8 SFF |
| Lifecycle Status | End of sale |
| End of Sale | 2025-05-23 |
| Processor Options | 2x 3rd Gen Intel Xeon Scalable (Ice Lake, to 40C/3.6GHz/270W) |
| Memory Configuration | 32x DDR4 RDIMM/3DS to 3200 MHz (16/CPU), max 4TB; up to 16x Optane PMem 200; ECC/ADDDC |
| Drive Configurations | SXM: 4-8x 2.5in NVMe; 4-DW: 8x 2.5in AnyBay or 4x 3.5in; 8-DW: 6x E1.S NVMe; + 2x M.2; max 245.76TB |
| Power Supply Options | Up to 4x hot-swap 1800W/2400W Platinum, 220V |
| RAID Controllers | Intel VROC SATA + NVMe; 12Gb SAS/SATA RAID adapters + HBAs |
| Networking Options | OCP 3.0 slot (PCIe 4.0), 1/10/25 GbE; XCC shared + dedicated |
| GPU Options | Up to 8x double-wide PCIe GPUs (8-DW) or 4x SXM (HGX A100 4-GPU, Neptune liquid-to-air) |
| Specification Source | Lenovo official documentation Lenovo Press LP1393 (lenovopress.lenovo.com) (verified 2026-07-02) |
Storage for ThinkSystem SR670 V2
200 storage configurations listed for the ThinkSystem SR670 V2, 1,536 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.
| Configuration | Parts | Example part numbers |
|---|---|---|
| 960 GB · SATA · 2.5" Small Form Factor (SFF) · Solid State (no rotational speed) | 52 | 01PE307, 4XB7A08503, 4XB7A10154 |
| 480 GB · SATA · 2.5" Small Form Factor (SFF) · Solid State (no rotational speed) | 50 | 4XB7A08502, 4XB7A10153, 4XB7A10196 |
| 1.92 TB · SATA · 2.5" Small Form Factor (SFF) · Solid State (no rotational speed) | 45 | 4XB7A08504, 4XB7A10155, 4XB7A10198 |
| 3.84 TB · SATA · 2.5" Small Form Factor (SFF) · Solid State (no rotational speed) | 45 | 4XB7A08505, 4XB7A10156, 4XB7A10199 |
| 3.84 TB · NVMe · 2.5" Small Form Factor (SFF) · Solid State (no rotational speed) | 42 | 4XB7A13942, 4XB7A13977, 4XB7A13998 |
| 7.68 TB · NVMe · 2.5" Small Form Factor (SFF) · Solid State (no rotational speed) | 37 | 4XB7A13943, 4XB7A17147, 4XB7A38270 |
| 240 GB · SATA · 2.5" Small Form Factor (SFF) · Solid State (no rotational speed) | 35 | 4XB7A10195, 4XB7A10237, 4XB7A10247 |
| 1.92 TB · NVMe · 2.5" Small Form Factor (SFF) · Solid State (no rotational speed) | 30 | 4XB7A13941, 4XB7A13976, 4XB7A17145 |
| 15.36 TB · NVMe · 2.5" Small Form Factor (SFF) · Solid State (no rotational speed) | 26 | 4XB7A13631, 4XB7A81954, 4XB7A82369 |
| 1.6 TB · NVMe · 2.5" Small Form Factor (SFF) · Solid State (no rotational speed) | 24 | 4XB7A13967, 4XB7A17129, 4XB7A17152 |
| 7.68 TB · SATA · 2.5" Small Form Factor (SFF) · Solid State (no rotational speed) | 24 | 4XB7A10157, 4XB7A10200, 4XB7A13624 |
| 3.2 TB · NVMe · 2.5" Small Form Factor (SFF) · Solid State (no rotational speed) | 21 | 4XB7A13970, 4XB7A17130, 4XB7A17153 |
| 7.68 TB · NVMe · Solid State (no rotational speed) | 21 | KCD8XRUG7T68, KCM61RUL7T68, KCM6XRUL7T68 |
| 14 TB · SAS · 3.5" Large Form Factor (LFF) · 7,200 RPM (7.2K) | 20 | 4XB7A13906, 4XB7A17224, MG07SCA14TA |
| 4 TB · SATA · 3.5" Large Form Factor (LFF) · 7,200 RPM (7.2K) | 20 | 4XB7A77447, 4XB7B01236, 4XB7B01927 |
| 3.84 TB · NVMe · Solid State (no rotational speed) | 19 | KCD8XRUG3T84, KCM61RUL3T84, KXDZDRJJ3T84 |
| 6.4 TB · NVMe · 2.5" Small Form Factor (SFF) · Solid State (no rotational speed) | 19 | 4XB7A13971, 4XB7A17133, 4XB7A17154 |
| 1.92 TB · NVMe · Solid State (no rotational speed) | 17 | KCM6XRUL1T92, KXD71RJJ1T92, MTFDKBZ1T9TDZ |
| 18 TB · SAS · 3.5" Large Form Factor (LFF) · 7,200 RPM (7.2K) | 17 | 4XB7A38266, 4XB7A76340, MG09SCA18TA |
| 8 TB · SATA · 3.5" Large Form Factor (LFF) · 7,200 RPM (7.2K) | 17 | 0B36418, 4XB7A17225, 4XB7A77449 |
| 1.92 TB · NVMe · U.2 · Solid State (no rotational speed) | 16 | 4XB7A10175, 4XB7A14059, 4XB7A38196 |
| 16 TB · SAS · 3.5" Large Form Factor (LFF) · 7,200 RPM (7.2K) | 16 | 4XB7A13911, 4XB7A80284, 4XB7A83978 |
| 3.84 TB · NVMe · U.2 · Solid State (no rotational speed) | 16 | 4XB7A10176, 4XB7A14060, 4XB7A38197 |
| 800 GB · SAS · 2.5" Small Form Factor (SFF) · Solid State (no rotational speed) | 16 | 01DC452, 01DC457, 01DC477 |
| Other storage parts | 95 | 4C57A85377, 4L47A83669, 4M17A37281 |
+176 more storage configurations (796 parts) →
Networking for ThinkSystem SR670 V2
19 networking configurations listed for the ThinkSystem SR670 V2, 651 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.
| Configuration | Parts | Example part numbers |
|---|---|---|
| SFP / SFP+ | 52 | 4XC7B00020, 7M17A04000, 7Z57A03541 |
| QSFP28 Ethernet Transceiver · 100G | 13 | QSFP-100G-B20D4-I, QSFP-100G-B20U4-I, QSFP-100G-DR-S |
| SFP+ Ethernet Transceiver · 10G | 13 | 407-BBOP, SFP-10G-BX40D-I, SFP-10G-BX40U-I |
| QSFP+ Ethernet Transceiver · 40G | 11 | 00FP652, 00W0039, 95Y3461 |
| QSFP28 Transceiver · 100G | 7 | MMA1B00-E100D, QSFP-100G-4W40-I, QSFP-100G-CWDM4-S |
| SFP+ Transceiver · 10G | 5 | 42C1816, 46C9297, 46W4236 |
| SFP Ethernet Transceiver · 1G | 4 | 407-BBOS, GLC-LH-SMD, GLC-SX-MMD |
| SFP+ Transceiver | 4 | FTLF8529P3BCV-QL, FTLF8529P4BCV-QL, FTLF8532P4BCV-QL |
| QSFP28 Ethernet Transceiver | 3 | MMA1B00-C100D, MMA1L30-CM, MMS1C10-CM |
| QSFP+ Transceiver · 40G | 2 | 00D9552, FET-40G |
| SFP28 Ethernet Transceiver | 2 | MMA2P00-AS, MMA2P00-AS-SP |
| SFP28 Ethernet Transceiver · 25G | 2 | SFP-25G-LR-S, SFP-25G-SR-S |
| SFP28 Transceiver · 10G | 2 | 4TC7A88638, 7G17A03537 |
| QSFP+ Ethernet Transceiver | 1 | MMA1T00-VS |
| QSFP+ Transceiver · 200G | 1 | MMA1T00-HS |
| QSFP28 Transceiver | 1 | CVR-QSFP28-SFP25G |
| SFP Transceiver | 1 | 4TC7A83365 |
| SFP+ Ethernet Transceiver | 1 | 7G17A03130 |
| SFP28 Transceiver · 25G | 1 | 4M27A67041 |
| Other networking parts | 525 | 00JY940, 00MM850, 00MM860 |
Controllers for ThinkSystem SR670 V2
49 controllers configurations listed for the ThinkSystem SR670 V2, 446 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.
| Configuration | Parts | Example part numbers |
|---|---|---|
| RAID Controller | 69 | 2275400-R, 2283400-R, 3204C8IX2S |
| SAS / SATA HBA | 44 | 05-25688-00, 05-50044-00, 05-50065-00 |
| Fibre Channel (FC) HBA | 43 | LPe31000-M6, LPe31002-M6, LPe31004-M6 |
| Fibre Channel (FC) HBA · PCIe · 16 Gb/s | 36 | LPe16000-M6, LPe16000B-AP, LPe16000B-M6 |
| Fibre Channel (FC) HBA · PCIe · 32 Gb/s | 33 | 4XC7A08250, 4XC7A08251, 4XC7A08276 |
| SAS / SATA HBA · PCIe | 30 | 03-25600-01B, 05-25600-00, 05-50118-00 |
| RAID Controller · NVMe | 22 | 3204C8IXS, 3254C16IX2S, 3254C16IXS |
| RAID Controller · SAS | 18 | 2279700-R, 2279800-R, 2279900-R |
| Fibre Channel (FC) HBA · 16 Gb/s | 16 | 7ZT7A00520, 7ZT7A00521, 7ZT7A00522 |
| Fibre Channel (FC) HBA · PCIe · 64 Gb/s | 16 | 4XC7A77485, 4XC7A96458, 4XC7A96744 |
| RAID Controller · SAS / SATA · 12 Gb/s | 15 | 2277500-R, 2277600-R, 2287101-R |
| RAID Controller · SAS / SATA · 6 Gb/s | 14 | 2270100-R, 2270800-R, 2271700-R |
| Fibre Channel (FC) HBA · 32 Gb/s | 11 | LPe32000-M2-D, LPe32000-M2-L, LPe32002-M2-D |
| Fibre Channel (FC) HBA · 64 Gb/s | 5 | LPe36000-D, LPe36000-M64-D, LPe36002-D |
| RAID Controller · SATA | 5 | 4XH7A60926, 4XH7A60977, 4XH7A80461 |
| PERC 9380- RAID Controller · SAS / SATA · 12 Gb/s | 4 | 05-25190-02, 05-25528-04, 05-25528-06 |
| PERC 9361- RAID Controller · SAS / SATA · 12 Gb/s | 3 | 05-25699-00, 05-25708-00, LSI00462 |
| RAID Controller · SAS / SATA | 3 | 2244100-R, 2244300-R, 4XH7A61096 |
| Fibre Channel (FC) HBA · PCIe · 8 Gb/s | 2 | 4XC7A08220, 4XC7A08221 |
| PERC 9240 RAID Controller · SAS · 6 Gb/s | 2 | 03T6739, 91Y1859 |
| PERC 9350- RAID Controller | 2 | 4Y37A72485, 4Y37A72486 |
| PERC 9350-8I RAID Controller | 2 | 4Y37A72483, 4Y37A72484 |
| PERC 9361-8I RAID Controller · SAS / SATA · 12 Gb/s | 2 | 05-25420-08, 05-25420-10 |
| PERC 9450- RAID Controller | 2 | 4Y37A97937, 4Y37A97940 |
| Other controllers parts | 20 | 05-50008-00, 05-50008-01, 05-50008-03 |
+25 more controllers configurations (27 parts) →
GPU for ThinkSystem SR670 V2
52 gpu configurations listed for the ThinkSystem SR670 V2, 366 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.
+28 more gpu configurations (45 parts) →
Memory for ThinkSystem SR670 V2
41 memory configurations listed for the ThinkSystem SR670 V2, 170 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.
| Configuration | Parts | Example part numbers |
|---|---|---|
| 32 GB · 3200 MHz · RDIMM ECC Registered | 14 | 4X77A08634, 4X77A12188, 4X77A77064 |
| 16 GB · 2666 MHz · RDIMM ECC Registered | 11 | 7X77A01302, 7X77A01303, HMA42GR7AFR4N-VK |
| 16 GB · 2933 MHz · RDIMM ECC Registered | 10 | 4X77A12184, 4ZC7A08707, 4ZC7A08708 |
| 16 GB · 3200 MHz · RDIMM ECC Registered | 10 | 4X77A08632, 4X77A85855, 4ZC7A15121 |
| 64 GB · 3200 MHz · RDIMM ECC Registered | 8 | 02JK971, 4X77A08635, 4X77A12189 |
| 16 GB · 2133 MHz · RDIMM ECC Registered | 7 | HMA42GR7AFR4N-TF, HMA42GR7BJR4A-TF, HMA42GR7MFR4N-TF |
| 16 GB · 2400 MHz · RDIMM ECC Registered | 7 | HMA42GR7AFR4N-UH, HMA82GR7AFR4N-UH, HMA82GR7AFR8N-UH |
| 32 GB · 2933 MHz · RDIMM ECC Registered | 7 | 4X77A12185, 4ZC7A08742, HMA84GR7CJR4N-WM |
| 8 GB · 2133 MHz · RDIMM ECC Registered | 7 | HMA41GR7AFR4N-TF, HMA41GR7AFR8N-TF, HMA41GR7BJR4N-TF |
| 8 GB · 2666 MHz · RDIMM ECC Registered | 7 | 7X77A01301, HMA41GR7BJR4N-VK, HMA41GR7BJR8N-VK |
| 128 GB · 3200 MHz · RDIMM ECC Registered | 6 | 4X77A08636, 4X77A75933, 4X77A91001 |
| 32 GB · 2666 MHz · RDIMM ECC Registered | 6 | 7X77A01304, HMA84GR7AFR4N-VK, HMA84GR7CJR4N-VK |
| 64 GB · 2933 MHz · RDIMM ECC Registered | 6 | 4X77A12186, 4ZC7A08710, 4ZC7A08744 |
| 64 GB · 2666 MHz · LRDIMM ECC | 5 | 4X77A78614, 7X77A01305, HMAA8GL7AMR4N-VK |
| 8 GB · 2400 MHz · RDIMM ECC Registered | 5 | HMA41GR7AFR4N-UH, HMA41GR7AFR8N-UH, HMA41GR7BJR4N-UH |
| 64 GB · 2666 MHz · RDIMM ECC Registered | 4 | 4ZC7A08716, HMAA8GR7AJR4N-VK, HMAA8GR7CJR4N-VK |
| 128 GB · 2666 MHz · LRDIMM ECC | 3 | HMABAGL7A4R4N-VN, HMABAGL7C4R4N-VN, HMABAGL7M4R4N-VN |
| 128 GB · 2666 MHz · RDIMM ECC Registered | 3 | 7X77A01307, HMABAGR7A4R4N-VN, HMABAGR7C4R4N-VN |
| 128 GB · 3200 MHz · LRDIMM ECC | 3 | HMABAGL7A4R4N-XN, HMABAGL7C4R4N-XN, HMABAGL7M4R4N-XN |
| 32 GB · 2400 MHz · RDIMM ECC Registered | 3 | HMA84GR7AFR4N-UH, HMA84GR7CJR4N-UH, HMA84GR7MFR4N-UH |
| 64 GB · 2400 MHz · LRDIMM ECC | 3 | HMAA8GL7AMR4N-UH, HMAA8GL7CPR4N-UH, HMAA8GL7MMR4N-UH |
| 64 GB · 3200 MHz · LRDIMM ECC | 3 | 4X77A08633, HMAA8GL7AMR4N-XN, HMAA8GL7CPR4N-XN |
| 128 GB · 2400 MHz · LRDIMM ECC | 2 | HMABAGL7A4R4N-UL, HMABAGL7M4R4N-UL |
| 128 GB · 2933 MHz · LRDIMM ECC | 2 | HMABAGL7A4R4N-WM, HMABAGL7C4R4N-WM |
| Other memory parts | 4 | RFQ-MEM-DDR4, RFQ-MEM-LRDIMM, RFQ-MEM-NVDIMM |
+17 more memory configurations (24 parts) →
Processors for ThinkSystem SR670 V2
58 processors configurations listed for the ThinkSystem SR670 V2, 164 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.
+34 more processors configurations (56 parts) →
Power Supplies for ThinkSystem SR670 V2
7 power supplies configurations listed for the ThinkSystem SR670 V2, 9 parts in total. Each row is one configuration ICD supplies; the part numbers are examples from that row.
| Configuration | Parts | Example part numbers |
|---|---|---|
| 1800W output · 80 PLUS Platinum | 2 | 4P57A26294, 4P57A78362 |
| 1800W output · 80 PLUS Titanium | 1 | 4P57A78359 |
| 2000W output · 80 PLUS Platinum, Hot-Swap | 1 | 7N67A00887 |
| 2000W output · 80 PLUS Titanium | 1 | 4P57A88689 |
| 2000W output · 80 PLUS Titanium, Hot-Swap | 1 | 4P57A95707 |
| 2400W output · 80 PLUS Platinum | 1 | 4P57A26295 |
| 2400W output · 80 PLUS Platinum, Hot-Swap | 1 | 4P57A69999 |
| Other power supplies parts | 1 | RFQ-SRV-PSU |
Post-Warranty Support for ThinkSystem SR670 V2
ICD Care+ TPM covers the ThinkSystem SR670 V2 past OEM end-of-support: parts and on-site support at SLA levels set per contract, typically 40-60% less than OEM post-warranty support.
Learn About ICD Care+ →Frequently Asked Questions — ThinkSystem SR670 V2
What power supply options does the ThinkSystem SR670 V2 support?
Up to 4x hot-swap 1800W/2400W Platinum, 220V
What processors does the ThinkSystem SR670 V2 support?
2x 3rd Gen Intel Xeon Scalable (Ice Lake, to 40C/3.6GHz/270W)
How much memory does the ThinkSystem SR670 V2 support?
32x DDR4 RDIMM/3DS to 3200 MHz (16/CPU), max 4TB; up to 16x Optane PMem 200; ECC/ADDDC
What drive configurations does the ThinkSystem SR670 V2 support?
SXM: 4-8x 2.5in NVMe; 4-DW: 8x 2.5in AnyBay or 4x 3.5in; 8-DW: 6x E1.S NVMe; + 2x M.2; max 245.76TB
What RAID and storage controllers does the ThinkSystem SR670 V2 use?
Intel VROC SATA + NVMe; 12Gb SAS/SATA RAID adapters + HBAs
What networking and connectivity does the ThinkSystem SR670 V2 offer?
OCP 3.0 slot (PCIe 4.0), 1/10/25 GbE; XCC shared + dedicated
What GPU and accelerator options does the ThinkSystem SR670 V2 support?
Up to 8x double-wide PCIe GPUs (8-DW) or 4x SXM (HGX A100 4-GPU, Neptune liquid-to-air)
What memory does ICD list for the ThinkSystem SR670 V2?
The memory modules listed are the component families ICD lists for the ThinkSystem SR670 V2; part-level fit is confirmed on every quote. Maximum capacity: 2TB DDR4. Module type, speed and rank are confirmed against your configuration on the quote.
Does ICD ship ThinkSystem SR670 V2 parts to Egypt, UAE, KSA?
Yes. Egypt: same-day in Cairo Metro or 1-2 days. North Africa: 2-4 days. GCC (Saudi Arabia, UAE, Kuwait, Qatar, Bahrain, Oman) and Levant: 3-4 days. East Africa: 4-6 days. West Africa: 5-7 days. Southern Africa: 5-8 days. Europe: 3-5 days. North America: 5-7 days. Asia: 4-7 days. Express door-to-door from Cairo via DHL, Aramex or FedEx; customs clearance may add 1-3 days. Exact transit time is stated per quote. For NTRA-regulated networking parts bound for Egypt, the import route is stated per quote.
Is the ThinkSystem SR670 V2 still supported?
No OEM end-of-support date is on record for the ThinkSystem SR670 V2. ICD Care+ TPM continues hardware support and parts at SLA levels set per contract.
How do I get a compatibility-verified quote?
Send your part list or workload requirement via the quote form or WhatsApp +20 104 022 22 14. We reply within 24 hours with a USD quotation matched by part number; the lead time is stated on each quote.
Are ICD parts for the ThinkSystem SR670 V2 new or refurbished?
Both, clearly labeled on every listing and quote: New, Renewed or Refurbished (tested). Every ICD part except consumables carries a warranty: 1 year included on drives, power supplies and other wear parts, 3 years included on CPUs, memory, networking and optics, and extendable up to 10 years.
Components Listed
Storage
Accessories
Networking
Controllers
GPU
Memory
Processors
Cooling
Power Supplies
Caddy / Tray
Related Resources
Need a custom configuration?
Our team can build a complete parts list for your ThinkSystem SR670 V2, with compatibility confirmed on the quote.
Get a Custom Quote