Trusted Since 2005| +202 2705 2005| [email protected]| 1 to 10 Year Warranty| Ships Worldwide to 100+ Countries| Every Part Tested & Warranted| 500,000+ Enterprise Parts| Dell · HPE · IBM · Lenovo · Cisco|Trusted Since 2005| +202 2705 2005| [email protected]| 1 to 10 Year Warranty| Ships Worldwide to 100+ Countries| Every Part Tested & Warranted| 500,000+ Enterprise Parts| Dell · HPE · IBM · Lenovo · Cisco

HPE ProLiant DL360 Gen10 vs DL360 Gen11 — Intel Xeon Scalable Gen1/Gen2 to Intel Xeon Scalable Gen4/Gen5 Upgrade Analysis

HPE ProLiant DL360 Gen10 vs DL360 Gen11 — Intel Xeon Scalable Gen1 to Intel Xeon Scalable Gen4 Upgrade Analysis

A side-by-side engineering and lifecycle comparison written for IT architects who have to decide between keeping the DL360 Gen10 running with ICD Care+ or refreshing to the DL360 Gen11 platform. All specs come from HPE QuickSpecs and ICD’s live catalog. 1U density teams in Cairo and Dubai face the same decision: stay on DDR4 Gen10 + ICD Care+, or leap to DDR5 Gen11 for five more years of OEM coverage.

At-a-glance specification table

SpecificationDL360 Gen10DL360 Gen11
Processor familyIntel Xeon Scalable Gen1/Gen2Intel Xeon Scalable Gen4/Gen5
Sockets22
Max memory3TB DDR4-29338TB DDR5-4800
DIMM slots2432
Drive bays8 SFF + 2 NVMe8+2 SFF / 20 EDSFF E3.S / 4 LFF
RAID / HBASmart Array P408i-a / E208i-aMR216i-p / MR416i-o
Out-of-band mgmtiLO 5iLO 6
PCIeGen3Gen5
Released20172023
HPE sale statusIn HPE end-of-life processActive SKU
HPE end of supportNot published by HPEHPE roadmap active
LifecycleEnd of SaleCurrent

CPU platform deep-dive

DL360 Gen10 ships with Intel Xeon Scalable Gen1/Gen2. The DL360 Gen10 uses the LGA3647 socket (Xeon Scalable Gen1/Gen2); the DL360 Gen11 moves to the LGA4677 socket (Xeon Scalable Gen4/Gen5), which adds Intel AMX matrix instructions for AI, so processors and heatsinks do not carry over.

DL360 Gen11 runs Intel Xeon Scalable Gen4/Gen5. The generational jump is meaningful even if your workload never touches AI — per-core IPC is roughly 35-55% higher, memory bandwidth is 2x at iso-channel, and PCIe moves from Gen3 to Gen5. For compute-bound Oracle, databases, or HPC codes the Gen11 delta alone can justify the migration.

Memory subsystem (DDR4 to DDR5)

Memory is the single biggest platform difference. The DL360 Gen10 uses 3TB DDR4-2933 across 24 DIMM slots. The DL360 Gen11 uses 8TB DDR5-4800 across 32 DIMM slots. Registered DIMMs (RDIMM) are not interchangeable between DDR4 and DDR5 — the notch position, pin count, and voltage regulator location all differ.

If you are consolidating from DL360 Gen10 and carrying your workload to DL360 Gen11, treat memory as a full new BOM — no re-use. Memory for a fully populated DL360 Gen11 (32 DIMM slots) is quoted per configuration, depending on capacity tier and memory condition.

Storage backplane + NVMe generation

The backplane generation is the second major delta. The DL360 Gen10 uses Smart Array P408i-a / E208i-a; the DL360 Gen11 uses MR216i-p / MR416i-o. Drive carriers between the two generations are mechanically similar for 2.5″ SFF bays, but carrier part numbers differ by generation — order drives in the carrier HPE QuickSpecs lists for the target server, at the drive firmware level HPE supports on its controller.

NVMe E3.S (EDSFF) is the biggest architectural shift — DL360 Gen11 in the Gen11/12 lineup supports dense EDSFF E3.S drives that were simply unavailable on DL360 Gen10. For object storage, Ceph, and high-IOPS Oracle ASM clusters this is transformative.

Power + cooling envelope

The DL360 Gen10 and the DL360 Gen11 use HPE power supplies validated per platform. Order the supplies HPE QuickSpecs lists for the DL360 Gen11: a supply that physically fits the bay is not necessarily on the DL360 Gen11 supported list.

Thermals matter: higher-TDP processors on the DL360 Gen11 can require the high-performance fan kit listed in HPE QuickSpecs rather than the standard fans used on the DL360 Gen10. Size rack power and cooling with HPE Power Advisor for the exact configuration.

Smart Array vs MR controller line

DL360 Gen10 ships with Smart Array P408i-a / E208i-a. DL360 Gen11 ships with MR216i-p / MR416i-o. Smart Array (SR) and Broadcom-based MR (MegaRAID) controllers are different families, each with its own firmware and management tools.

Operationally this matters for three reasons. First, cache protection: write-back cache is protected by an HPE Smart Storage Battery, and the kit (for example 871264-001 with a 145 mm cable or P01367-B21 with a 260 mm cable) depends on the controller and chassis, as listed in HPE QuickSpecs. Second, management: Smart Array controllers are managed with HPE Smart Storage Administrator (SSA), while MR controllers use HPE MR Storage Administrator and StorCLI. Third, arrays do not move between the two families: Smart Array and MR controllers write different array metadata, so data is migrated by replication rather than by moving the drives.

iLO generation differences

Out-of-band management evolves across this transition. DL360 Gen10 ships iLO 5. DL360 Gen11 ships iLO 6. iLO 6 introduces the Security Dashboard, Silicon Root of Trust with Secure Supply Chain, and hardware-enforced firmware rollback protection. If your compliance posture requires FIPS 140-3, iLO 6 is a real differentiator. iLO 5 on Gen10 still receives security patches through HPE iLO 5 firmware train — but new CVE coverage for iLO 6 lands first and is deeper. RESTful API parity exists between iLO 5 and iLO 6, but payload schemas changed — scripted remediation tooling (Ansible, Redfish, iLOrest) needs re-validation.

Parts crossover list (real PNs from the ICD catalog)

SubsystemDL360 Gen10 (real HPE PNs)DL360 Gen11 (real HPE PNs)
CPU kitsXeon Scalable Gen1/Gen2 processors (kit part numbers are specific to each chassis, quoted for your exact server)Xeon Scalable Gen4/Gen5 processors (kit part numbers are specific to each chassis, quoted for your exact server)
MemoryP00922-B21 (16GB RDIMM DDR4-2933), P00924-B21 (32GB RDIMM DDR4-2933), P00930-B21 (64GB RDIMM DDR4-2933)P43328-B21 (32GB RDIMM DDR5-4800), P43331-B21 (64GB RDIMM DDR5-4800), P50311-B21 (32GB 2Rx8 DDR5-4800)
Storage controller804331-B21 (P408i-a SR Gen10), 804338-B21 (P816i-a SR Gen10), 804326-B21 (E208i-a SR Gen10)P26324-B21 (MR216i-a 12G), P26279-B21 (MR416i-a 12G), P06367-B21 (MR416i-p 12G)
Power supply865414-B21 (800W FS Platinum), 865408-B21 (500W FS Platinum)P38995-B21 (800W FS Platinum), P18224-B21 (800W FS Titanium)

Reference part numbers carried in the ICD catalog

  • DL360 Gen10 CPU: Xeon Scalable Gen1/Gen2 processors (kit part numbers are specific to each chassis, quoted for your exact server)
  • DL360 Gen10 Memory: P00922-B21 (16GB RDIMM DDR4-2933), P00924-B21 (32GB RDIMM DDR4-2933), P00930-B21 (64GB RDIMM DDR4-2933)
  • DL360 Gen10 Controller: 804331-B21 (P408i-a SR Gen10), 804338-B21 (P816i-a SR Gen10), 804326-B21 (E208i-a SR Gen10)
  • DL360 Gen10 Power: 865414-B21 (800W FS Platinum), 865408-B21 (500W FS Platinum), 865438-B21 (800W FS Titanium), P03159-001 (1000W FS Titanium)
  • DL360 Gen11 CPU: Xeon Scalable Gen4/Gen5 processors (kit part numbers are specific to each chassis, quoted for your exact server)
  • DL360 Gen11 Memory: P43328-B21 (32GB RDIMM DDR5-4800), P43331-B21 (64GB RDIMM DDR5-4800), P50311-B21 (32GB 2Rx8 DDR5-4800), P50312-B21 (64GB 2Rx4 DDR5-4800), P43334-B21 (128GB DDR5-4800 3DS)
  • DL360 Gen11 Controller: P26324-B21 (MR216i-a 12G), P26279-B21 (MR416i-a 12G), P06367-B21 (MR416i-p 12G), P04220-B21 (SR416i-a 24G Tri-Mode), P12688-B21 (SR416i-a 24G)
  • DL360 Gen11 Power: P38995-B21 (800W FS Platinum), P18224-B21 (800W FS Titanium)

When to keep, when to upgrade

Keep your DL360 Gen10 and extend via ICD Care+ when: workloads are steady-state, IOPS ceiling is well below 12G SAS saturation, DDR capacity already meets 12–18 month forecast, and HPE’s EOSL date for your chassis still gives 24+ months of official support runway. ICD Care+ third-party maintenance picks up coverage at 40-60% below HPE’s post-warranty OEM rate, extending practical life 3–5 years past EOSL without a capital refresh.

Migrate to DL360 Gen11 when: you need DDR5 bandwidth for analytics/in-memory DB, your vCPU-to-physical ratio is already uncomfortable, your compliance program requires FIPS 140-3 attestation (iLO 6), or your consolidation roadmap calls for 2:1 or higher node consolidation.

ICD perspective + supply posture

ICD supplies both generations. For Cairo, Dubai, Riyadh, Kuwait, Doha, Casablanca and Lagos deployments we ship tested refurbished DL360 Gen10 from Cairo (same-day in Greater Cairo or 1–2 days within Egypt, 3–4 days to the GCC, 2–4 to Casablanca, 5–7 to Lagos), and BTO DL360 Gen11 with HPE OneView licensing and iLO 6 Advanced from our distributor partners. Every unit goes through ICD’s 17-point bench test, firmware sync to the latest HPE SPP train, and serial number registration with HPE Asset Manager before it leaves the facility.

If you are operating mixed fleets — common in banks, telcos, and manufacturing MES environments — ICD Care+ TPM covers both DL360 Gen10 and DL360 Gen11 under a single contract, which removes the patchwork maintenance matrix most customers inherit after a multi-year refresh cycle.

Third-party maintenance bridge

HPE’s post-warranty pricing escalates sharply beyond year 5. ICD Care+ TPM holds coverage at 40-60% below HPE’s equivalent, includes on-site support with SLA levels set per contract, and supplies tested HPE parts. For fleets approaching EOSL that aren’t ready for a full refresh, Care+ is often the difference between a full fleet refresh in year 6 and a TPM contract covering years 6-10.

Quick decision framework: If your DL360 Gen10 is still under HPE support and your workload is steady-state → keep. If HPE support ended or ends within 12 months and you need DDR5 bandwidth, iLO 6 Security Dashboard, or consolidation ratio → migrate to DL360 Gen11. If budget is tight but you can’t tolerate loss of coverage → ICD Care+ on the DL360 Gen10 for 24-36 months while you plan the refresh.

Need a real BOM for your fleet?

ICD sends back a config-ready quote in 24 hours, not 7 days.

Request an HPE Quote

Frequently Asked Questions

Can a Gen10 800W Flex Slot power supply go into a DL360 Gen11?

It physically fits, but it is not supported. The Gen10 865414-B21 800W Platinum unit seats in a Gen11 bay, yet it is not on HPE's validated configuration list because efficiency ratings and power cap firmware profiles were re-baselined. Gen11 options include P38995-B21 800W Platinum and P18224-B21 800W Titanium.

When does HPE support end for the DL360 Gen10?

The DL360 Gen10 is in HPE's end-of-life process, and HPE has published no public end-of-sale or end-of-support date. The DL360 Gen11, released in 2023, is an active SKU. Keeping a Gen10 is reasonable for steady-state workloads while at least 24 months of official support runway remain.

Why choose iLO 6 on the Gen11 for a compliance-driven environment?

iLO 6 adds the Security Dashboard, Silicon Root of Trust with Secure Supply Chain and hardware-enforced firmware rollback protection. If your compliance program requires FIPS 140-3 attestation, it is a real differentiator over iLO 5. Note that payload schemas changed, so Ansible, Redfish or iLOrest scripts need re-validation.

What drive layouts does the 1U DL360 Gen11 support compared with Gen10?

The DL360 Gen10 offers 8 SFF bays plus 2 NVMe, while the Gen11 offers 8+2 SFF, 20 EDSFF E3.S or 4 LFF bays. The Gen11 uses MR216i-p and MR416i-o controllers in place of the Gen10 Smart Array P408i-a and E208i-a.