Trusted Since 2005| +202 2705 2005| [email protected]| 1 to 10 Year Warranty| Ships Worldwide to 100+ Countries| Every Part Fully Tested & Certified| 500,000+ Enterprise Parts| Dell · HPE · IBM · Lenovo · Cisco|Trusted Since 2005| +202 2705 2005| [email protected]| 1 to 10 Year Warranty| Ships Worldwide to 100+ Countries| Every Part Fully Tested & Certified| 500,000+ Enterprise Parts| Dell · HPE · IBM · Lenovo · Cisco

Cisco RAID Controllers Nigeria | Cisco UCS Compatible

Cisco RAID in Nigeria

For Nigerian operators running Cisco UCS in Lagos and Abuja colocation, the storage controller is the part you most want to get right the first time — a foreign-config or wrong-generation card can leave an array offline while a replacement is sourced. Whether the design calls for hardware RAID with protected cache or HBA pass-through for software-defined storage, the controller has to match the server and the architecture. ICD supplies genuine Cisco UCS RAID controllers and SAS HBAs into Nigeria through Lagos port, exact-PID matched.

Cisco controllers and HBAs for Nigeria

The range covers 12G SAS RAID controllers with FBWC, modular SAS HBAs and M.2 boot controllers. Common choices include the Cisco 12G SAS RAID Controller with 4GB FBWC (16 Drives) and the Cisco 12G Modular SAS HBA for up to 26 drives.

PIDTypeCapacity / modeFits
UCSC-RAID-T12G SAS RAID16 drives, 4GB FBWCUCS C-Series
UCSC-SAS-M5HD12G SAS HBA26 drives, JBODUCS C-Series M5
UCSC-RAID-M512G SAS RAIDFBWCUCS C-Series M5
M2-NVRAIDM.2 NVMe RAIDBoot mirrorOS boot

Get the controller right before it ships

Because rapid local controller swaps are harder to arrange than in mature markets, matching the part precisely up front avoids a costly second shipment. Three checks do most of the work. Mode: a RAID controller builds protected hardware volumes and carries flash-backed write cache (FBWC) with a Supercap to guard cached writes on power loss; an HBA in JBOD mode exposes raw disks for vSAN, HyperFlex or Ceph — pick the one your stack expects, since converting later means rebuilding the array. Generation: M5, M6 and M7 controllers are not interchangeable; the card must match the server model. Boot: keep the OS on the dedicated M.2 RAID controller so a data rebuild never touches the boot volume. Holding an exact-PID cold spare for a critical node closes the resilience gap where same-day support is thin.

Tel: +202 27052005Email: [email protected]

Lagos import and delivery

ICD routes Nigerian controller orders through Lagos port and serves the Lagos and Abuja data-centre clusters — Rack Centre, MainOne/Equinix and others. Cisco controllers ship serial-traceable and warranty-backed, matched to your exact server up front.

Before you order

  • Confirm RAID vs HBA/JBOD mode against your storage architecture.
  • Match controller generation (M5 / M6 / M7) to the UCS server.
  • Verify FBWC + Supercap on RAID controllers for write protection.
  • Keep boot on the dedicated M.2 RAID controller.
  • Stock an exact-PID cold spare for critical nodes.
Worldwide Shipping

Fast delivery to 100+ countries

Tested & Certified

Every part fully tested before shipping

Enterprise Grade

Dell, HPE, Lenovo & Cisco parts

Dedicated Support

Expert team for quotes & technical help