Trusted Since 2005| +202 2705 2005| [email protected]| 1 to 10 Year Warranty| Ships Worldwide to 100+ Countries| Every Part Tested & Warranted| 500,000+ Enterprise Parts| Dell · HPE · IBM · Lenovo · Cisco|Trusted Since 2005| +202 2705 2005| [email protected]| 1 to 10 Year Warranty| Ships Worldwide to 100+ Countries| Every Part Tested & Warranted| 500,000+ Enterprise Parts| Dell · HPE · IBM · Lenovo · Cisco

Cisco Power Supplies Egypt | Cisco UCS Compatible

A power supply is the one component in a Cisco UCS or Catalyst chassis where a wrong choice shows up as an outage, not just slower performance. Wattage has to cover the populated configuration, redundancy mode has to match how the platform shares load, and airflow direction has to agree with the rest of the rack. ICD supplies genuine Cisco power supplies from Cairo — UCS Fabric Interconnect, rack-server and Catalyst/Nexus switch PSUs — matched to the exact SKU, so a redundant pair stays a redundant pair after replacement.

Cisco PSU SKUs available to order

The range covers AC and DC units across the UCS and Catalyst/Nexus families. Common requests include the Cisco UCS 6332/6454 650W AC Power Supply for Fabric Interconnects and the Cisco UCS 1050W DC Power Supply for DC-fed rack servers.

SKUWattageInputFits
PSU-6332-AC650WACUCS 6332 / 6454 FI
UCSC-PSUV2-1050DC1050WDCUCS C-Series (DC plant)
NXA-PAC-1100W1100WAC (fwd airflow)Nexus switches
PWR-C1-1900WAC-P1900WACCatalyst 9300
Tel: +202 27052005Email: [email protected]

Wattage, redundancy and airflow — the three checks

First, wattage headroom: size the PSU to the fully-populated server or switch — CPUs, all DIMMs, drives and any GPUs — not the as-shipped base, and leave margin. Second, redundancy mode: UCS supports N+1 and grid (N+N) redundancy, and both PSUs in a pair must be the same wattage and type or the chassis will not hold true redundancy; a mismatched pair can fall back to non-redundant. Third, airflow direction: Catalyst and Nexus PSUs ship in port-side-intake and port-side-exhaust variants — installing the wrong airflow disrupts the hot-aisle/cold-aisle design and can trip thermal protection. AC and DC are never interchangeable; the unit must match the facility’s power feed.

Power feeds and supply in Egypt

Egyptian facilities run a mix of straight AC and DC plant, especially in the larger Cairo, Smart Village and New Administrative Capital builds. As ICD’s home market, local supply means a failed PSU in a redundant pair gets its exact-SKU twin quickly, through our daily Cairo import handling — before the surviving unit becomes a single point of failure. All Cisco PSUs ship serial-traceable and warranty-backed.

Before you order

  • Confirm AC vs DC to match the facility power feed.
  • Size wattage to the fully-populated configuration, with margin.
  • Match wattage and type to the existing PSU in a redundant pair.
  • Check airflow direction (intake vs exhaust) against the rack layout.
  • Have the exact PSU SKU and host platform model ready.
Tel: +202 27052005Email: [email protected]
Worldwide Shipping

Fast delivery to 100+ countries

Tested & Warranted

Every part fully tested before shipping

Enterprise Grade

Dell, HPE, Lenovo & Cisco parts

Dedicated Support

Expert team for quotes & technical help