Trusted Since 2005| +202 2705 2005| [email protected]| 1 to 10 Year Warranty| Ships Worldwide to 100+ Countries| Every Part Fully Tested & Certified| 500,000+ Enterprise Parts| Dell · HPE · IBM · Lenovo · Cisco|Trusted Since 2005| +202 2705 2005| [email protected]| 1 to 10 Year Warranty| Ships Worldwide to 100+ Countries| Every Part Fully Tested & Certified| 500,000+ Enterprise Parts| Dell · HPE · IBM · Lenovo · Cisco

Cisco HDD Egypt | Cisco UCS Compatible

For Egyptian operators running Cisco UCS C-Series and B-Series infrastructure, the spinning disk still carries the bulk-capacity tier — archive, backup repositories, video surveillance and cold object storage where cost-per-terabyte beats flash. ICD supplies genuine Cisco-branded SAS HDDs from its Maadi, Cairo base, so a failed drive in a Smart Village or New Administrative Capital data hall can be matched by exact PID instead of an approximate substitute. Every drive we ship is firmware-keyed to the UCS controller it belongs in, which is what keeps a rebuild from stalling on an “unsupported device” flag.

Cisco SAS HDD models we supply

Cisco’s enterprise drive line spans 10K-RPM 2.5″ SFF performance disks through 7.2K-RPM 3.5″ LFF nearline capacity disks, in both 512e and native 4Kn sector formats. Common movers include the Cisco 1.8TB 12G SAS 10K 2.5 SFF 4Kn HDD for UCS for performance pools and the Cisco 8TB 7.2K 12G SAS 3.5 LFF 4Kn HDD for capacity racks.

PIDCapacityForm factor / sectorFits
HD18TB10K4KN1.8TB 10K2.5″ SFF / 4KnUCS C220/C240 M5–M6
HD24TB10K4KN2.4TB 10K2.5″ SFF / 4KnUCS C-Series SFF bays
HD8T7KL4K8TB 7.2K3.5″ LFF / 4KnUCS C240 LFF / S3260
HD600G15K12N600GB 15K2.5″ SFF / 512NLatency-sensitive pools

4Kn versus 512e — and why it matters at provisioning

The single decision that trips most Egyptian deployments is sector format. Native 4Kn drives expose 4096-byte physical and logical sectors; 512e drives emulate the legacy 512-byte logical sector over a 4K physical one. Mixing the two inside a single RAID group is not supported, and a 4Kn disk will not boot a legacy hypervisor that lacks 4Kn awareness. For new C240 capacity pools we recommend standardising on 4Kn from the start; for drop-in replacement into an existing array, match the format of the disks already present. Where data-at-rest compliance is required, Cisco’s SED (Self-Encrypting Drive) variants pair with the UCS controller’s local key management — note that SED and non-SED disks should not be mixed in one secured volume.

Sourcing and import into Egypt

As ICD’s home market, Egypt gets the fastest path: drives we source clear the on-the-ground import handling our Cairo team runs daily, so there is no waiting on a cross-border consolidation leg. That matters most for a degraded array where a second disk loss means data loss. We serve the Greater Cairo data-centre corridor — Smart Village, Maadi, and the New Administrative Capital build-out — alongside Alexandria and Delta sites, with serial-traceable Cisco hardware and warranty-backed parts.

Running this hardware past Dell’s support date? See Cisco end-of-life support in Egypt for parts and maintenance cover.

Before you order

  • Confirm the exact PID on the drive label or via show storage local-disk detail in UCS Manager / CIMC.
  • Match sector format (4Kn vs 512e) to the existing RAID group — never mix.
  • Verify form factor against your chassis bays: 2.5″ SFF vs 3.5″ LFF carriers differ.
  • For secured volumes, keep SED and non-SED drives separate.
  • Have your UCS server generation (M5 / M6 / M7) ready so we confirm controller compatibility.
Tel: +202 27052005Email: [email protected]